Expert Access Flag; Reset System Data - RESEARCH CONCEPTS RC2000A DUAL AXIS Instructions Manual

Antenna controller
Table of Contents

Advertisement

50
RC2000A Dual Axis Antenna Controller
4.10.9

Expert Access Flag

This CONFIG mode item is used to toggle the state of the Expert Access Flag. When the Expert
Access Flag is set (ON), the user has access to all controller modes and all CONFIG mode items.
When the Expert Access Flag is reset (OFF), the user is locked out of several modes and most
CONFIG mode items. This purpose of this feature is to keep an operator away from the modes and
CONFIG mode items which can allow an operator to change the contents of the controller's non-volatile
memory.
When the Expert Access screen is displayed, the present state of the Expert Access Flag is displayed in
the data entry field. A display value of 1 indicates that the Expert Access Flag is set, and a value of 0
indicates that the flag is reset. To toggle the state of the flag, either from set (1) to reset (0) or reset (0)
to set (1), the user must key in a 5 digit code at the prompt followed by the ENTER key. This code is
found in a removable appendix (Appendix A) at the end of this manual. If the information is lost, call the
factory for assistance.
The Expert Access screen can also be used to enter into the satellite band modification screen "BAND
EDIT". Refer to section 4.4.3 Satellite Band Edit.
EXPERT ACCESS (0-OFF, 1-ON):
ENTER CODE TO TOGGLE ENT,BKSP,SCRLL ^v
4.10.10

Reset System Data

This CONFIG mode data item is used to reset the controllers non-volatile memory. When this occurs,
the azimuth and elevation limits are invalidated and each of the various CONFIG mode items are
initialized to a default value. This operation is usually performed at the factory. Access to this item is
allowed only when the Expert Access Flag is set. To reset the system memory, the user must key in
the same 5 digit code, followed by the ENTER key.
RESET SYSTEM DATA:
ENTER CODE
Here are the default values which are assigned to non-volatile memory.
Azimuth Position Count: 5000
Azimuth CCW Limit:
Azimuth CW Limit:
Azimuth Limit Checksum:
Elevation Position Count:
Elevation Down Limit:
Elevation Up Limit:
Elevation Limit Checksum:
AutoPol Enable:
AutoPol Vpol Level:
Simultaneous Az/El Enable:
Remote Mode Enable:
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA
Chapter 4
1 CONFIG
0
CONFIG
ENT,BKSP,SCRLL ^v
4999
5001
Invalid - So the 'AZIM LIMITS ERROR'
alarm is displayed.
5000
4999
5001
Invalid
0
1 (Vertical)
0 (Disabled)
0 (Disabled)
Modes
www.researchconcepts.com

Advertisement

Table of Contents
loading

Table of Contents