20.3

Overload protection

L
While travelling downhill, the generated power is diverted into the storage batteries – the drive
motors work like a generator in this case. If you have fully charged your PR 25 before travelling
downhill, the security system switches to emergency stop in order to avoid damage to the electrical
system (control, electronics, etc.).
L
Active (triggered) overload protection is indicated by gradual braking until the PR 25 comes to a
standstill.
20.3.1

Reset the triggered overload protection:

>
Switch on the power generators, e.g. lighting. The generated excess power is now immediately used again.
>
The PR 25 is ready for operation again.