Email Messages Provide Error Notification - ATTO Technology FibreBridge 2370E Installation And Operation Manual

Atto technology fibrebridge 2370e embedable board level: user guide
Hide thumbs Also See for FibreBridge 2370E:
Table of Contents

Advertisement

Severity
Event
Level
Temperature
Warning
Unit Attention
Info
Unit Power On
Info
Voltage
Info
Voltage
Critical
Voltage
Warning

Email messages provide error notification

Email notification allows the FibreBridge to send an
Email message to you, a network administrator or
other users when certain events occur. Serious error
messages are sent immediately, while messages for
less serious errors are sent every 15 minutes.
You may send Emails to up to five Email addresses
and designate which conditions prompt each Email
notification.
When an event occurs that has been designated as
requiring Email notification, the FibreBridge sends the
message; it cannot respond to a rejection by a server
for an invalid address. Ensure all Email addresses
typed in are valid.
Each Email is time stamped when it leaves as part of
the SMTP header information as shown in Exhibit 3.0-
5.
1
If you are not already in the ExpressNAV
interface, type the IP address of your
21
ATTO Technology Inc. FibreBridge Installation and Operation Manual
Extended
Extended
Traps disabled
Traps enabled
Yes
No
Yes
Yes
Yes
Yes
Yes
Unit's internal temperature has increased to at or
within the unit's maximum operating temperature
less the unit's temperature warning offset or
decreased to at or within the unit's minimum
operating temperature plus the unit's temperature
warning offset.
Yes
A SCSI command discovers a unit attention
condition has occurred.
Yes
The unit has been powered up.
Yes
A monitored voltage level has increased or
decreased to within standard operating ranges.
Yes
A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
...
Level
VDDA
.............
3.30V
.......
..............
Low
5%
....
............
High
8%
Yes
A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
...
Level
VDDA
.............
3.30V
.......
..............
Low
3%
.....
..........
High
5%
FibreBridge in a standard browser as found in
Using ExpressNAV
Here, type in your user name and password,
and click OK .
2
On the left hand menu, click Remote Mgt .
3
The Remote Management page appears.
4
Click on the enabled radio button next to the
Email Notification heading.
5
Type in the sender address (Emails show this
name in the From field)
6
Type in the SMTP Server IP address
7
Type in the user name and password of your
SMTP Email account if your server requires it
8
Type in up to five Email addresses
9
Choose All , Informational, Warning, or
Critical for each Email address.
10 When all information is typed in, click Submit .
Explanation
......
..... .
........
VDDB
VDDC
.........
........
.........
2.50V
1.50V
............
.........,..
4%
5%
..... ....
............
5%
5%
......
..... .
........
VDDB
VDDC
.........
........
.........
2.50V
1.50V
..........
.........,..
3%
3%
... ......
..........
3.5%
3%
on page 25, click Enter
VDDD
1.35V
4.5%
5%
VDDD
1.35V
3%
3%

Advertisement

Table of Contents
loading

Table of Contents