 3.8 ELECTRICAL INSTALLATION (machines with remote AIR condensation)
The electrical system to which the machine is connected must be perfectly executed by a Qualified
electrician in compliance with current regulations. An efficient electrical system with adequate
earthing is of vital importance to ensure trouble-free operation of your machine.
We recommend installing an automatic wall differential switch. See tables below for power and absorption data
depending on the machine and voltage.
The line cable has five wires: the yellow/green wire is the earth, the blue wire is the Neutral and the other three are the
MANTE 1545
Total power
Maximum absorption
Line cable N. wires and section
MANTE 2060
Total power
Maximum absorption
Line cable N. wires and section
 3.9 WATER INSTALLATION AND CONSUMPTION
Connect the fitting with the writing ENTRATA ACQUA - WATER INLET to the hose from the water mains; connect the
fitting with the writing USCITA ACQUA - WATER OUTLET to the drain hose.
If the machine works with mains water supply (medium temperature 20°C), make sure that the water coming into the
machine has a minimum pressure of 1.5 bar. If the water pressure is above 5 bar, have the plumber mount a pressure
reducer that reduces it to 4 bar.
The average consumption of non salty mains or well
water (when the refrigerator system works) is:
- MANTE 15 45 =
- MANTE 20 60 =
* depending on inlet water temperature
If the water contains any impurities, it will be absolutely essential to fit a purifying filter to avoid any danger of
build-up of scale and/or damage to the pressure valve and condenser of the refrigerator system.
22
three phases.
KW.
A.
KW.
A.
100/190
litres/hour*
150/250
litres/hour*
V.220
V.220
50 HZ
60 HZ
4 x 4 mm²
4 x 4 mm²
V.220
V.220
50 HZ
60 HZ
4 x 6 mm²
4 x 6 mm²
If the machine works with Tower water, this must have a
maximum inlet temperature of 29°C.
The amount of water that must circulate at a minimum
pressure of 2.5 Bar must be:
- MANTE 15 45 =
- MANTE 20 60 =
* depending on inlet water temperature
V.400
50 HZ
5
16
4 x 2.5 mm²
V.400
50 HZ
6
21
4 x 4 mm²
300/600
litres/hour*
450/750
litres/hour*