 3.3
How to position and connect the water and electricity to the water
condensing machine
Valid for: MANTE 15 45
WARNINGS:
For good functioning, the machine does not require anchoring to the floor, or are technical precautions necessary to limit
vibrations.
There are, however, a number of important rules which must be followed:
Provide a 5 cm space between one machine and the other, essential for the hot air produced by the machine to
easily disperse from the bodywork louvres.
Ascertain machine stability by blocking the brakes of the front wheels using the feet (do not use hands).
Electrically connect the machine (E) ensuring the electric cable comes from above to avoid it being crushed if laid
on the floor. For power, voltage and absorption data, before powering, check the serial plate M to ensure they
correspond with those of the customer.
Connect the water supply to the machine (W) with water load and drain for condensing the refrigerator system.
Connect the water HW, hot or cold, for washing the machine. The water pressure must be at least 1.5 Bar and must
not exceed 4 Bar. The used rubber hoses must resist to 10 Bar of pressure and must be long enough to move the
machine forward by 50 cm, to enable cleaning the rear. The R fittings have a ¾" diameter thread Gas for MANTE 20
60 and MANTE 30 100; of ½" Gas for MANTE 15 45.