 3.7 How to position and connect the remote air condenser
REFRIGERATION
TECHNICIAN
To avoid air overheating problems, when possible, mount the remote air condenser.
ATTENTION:
The copper or flexible piping (T) bringing the Refrigerator gas from the machine to the condenser and vice-versa, must
not be longer than 4 metres.
The condenser must be fixed on to wall brackets in high position (2.5 m) so that it cannot be reached with hands by
persons of average height.
As in figure, the condenser must be away from the wall by at least 300 mm, so that the air can be drawn without
problems. It would also be useful to place a small protective roof against rain water.
The machine must be connected by a refrigeration technician who will subsequently check that the amount of Gas inside
the machine is suitable for best functioning.