 3.6
How to position and connect the water and electricity to the water/air
condensing machine
ELECTRICIAN
PLUMBER
Valid for: MANTE 15 45
MANTE 20 60 Air/Water
Connections are the same as the water condensing machine (see page
). Having, in addition, the CA air condenser, it
is possible to choose whether to condensate with air only or, if very hot, with water and air together.
It is very important to position the machine in a large environment, w ith doors and w indow for the air overheated
by the machine is refreshed. It is essential that the rear of the machine is at least 0.5 m away from the wall.
TECHNOGEL spa DOES NOT ANSWER FOR DAMAGES CAUSED BY MACHINE POSITIONING IN UNSUITABLE
ENVIRONMENTS. ALSO, IT DOES NOT ANSWER FOR DROPS IN YIELD OF THE MACHINE OBTAINED BY
WORKING IN LIMIT CONDITIONS.
20