5 - Remove the plug (B) to drain the water from the
plate.
6 - Remove the drip tray (C) and drain it.
7 - Clean the plate thoroughly with a sponge, rinse
with plenty of water and dry.
CHECKING GAS PRESSURE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Undo the screw (D) of the pressure connection.
5 - Connect the pressure gauge (E) to the pressure
test point (F).
6 - Turn the gas supply tap back on.
7 - Light the burner and turn the knob to the full
flame setting (see page 9), then check that the
pressure reading complies with the values in
the table (see back of manual).
8 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
9 - Restore the initial conditions after completing
the operation.
Important
Rinse the cooking plate thoroughly to re-
move all residues of the degreasing deter-
gent, and prevent stains and marks from
forming when the plate is put back into use.
A
B
B
C
- 15 -
E
F
D