Angelo Po 090FT1G Use And Installation Manual page 31

Cooking plate (fry - top)
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 27
Main Parts
A)Cooking plate: produced in a variety of shapes
and materials to meet the different requirements
B)Fume exhaust vent (Type A): for removal of the
fumes generated by the burner
C)Drain plug: for draining cooking residues into the
drip tray
D)Burner control knob: controls the supply of gas to
the burner
E)Ignition button: switches the burner on
F) Drip tray: collects the cooking residues
G)Gas supply connection: for connection of the gas
supply
H)Fume exhaust vent (type B11): removes the fumes
and conveys them to a flue with natural draft and with
draught damper device (for version 190FT only)
TECHNICAL DATA
See tables and "Connection chart" at the back of
the manual.
SAFETY DEVICES
Although the appliance is complete with all safety
devices, during installation and connection addi-
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
The illustration shows the position of the devices.
A)Gas supply tap: for turning the connection to the
gas supply line on and off.
B)Safety thermocouple: cuts out the gas supply if
the flame goes out.
C)Safety thermostat: cuts off the gas supply in
case of overheating (for chromium-plated only)
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
H
A
C
D
F
L) Fume exhaust vent (type B11): removes the fumes
and conveys them to a flue fitted with an extraction
system serving the gas system (for version 190FT
only)
B
C
B
- 5 -
L
B
G
E
IDM-39614700100.tif
A
IDM-39614700200.tif
English
IT
GB
DE
FR
ES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents