All roof-chimney terminations should be able
to be readily removed / re-installed at or
below an elevation of 13-1/2 feet (4.1 m)
above ground level without the use of special
tools or instructions. The chimney assembly
shall
be
provided
securement means to secure the chimney to
the ceiling support box.
When a chimney exits the mobile home at a
location other than through the roof, and
exits at a point 7 feet (2.1 m) or less above the
ground level on which the mobile home is
positioned, a guard or method of enclosing
the chimney shall be provided at the point of
exit for a height up to 7 feet.
The chimney guard shall not allow the
passage of a ¾ inch (19.1 mm) diameter rod,
and a ½" (12.7 mm) diameter rod shall not be
able to touch the chimney when inserted
through any part of the guard a distance of 4
inches (102 mm).
Hearthstone Quality Home Heating Products, Inc ®
with
a
mechanical
The chimney shall be provided with a spark
arrester secured to the chimney. The net free
area of the arrester above the chimney outlet
shall not be less than 4 times the net area of
the chimney outlet, and the vertical height of
the arrester above the chimney outlet shall
not be less than ½ the diameter of the
chimney flue. Openings shall not permit the
passage of a sphere having a diameter of ½
inch (12.7 mm), and shall allow the passage
of a sphere of 3/8" (9.6 mm).
Be sure to follow the manufacturer's
instructions to maintain an effective vapor
barrier at the location where the chimney of
other component penetrates the exterior of
the structure.
CAUTION: REMOVE THE CHIMNEY
WHEN TRANSPORTING THE MOBILE
HOME!