CAUTION!
Danger from faulty or incorrect holes.
This may lead to injuries to the eyes and hands as a result of flying debris and sharp
edges, as well as damage to the inverter.
When drilling, wear suitable protective goggles.
Only use a step drill when drilling.
Ensure that nothing is damaged inside the device (for example, connection block).
Adapt the diameter of the hole to match the corresponding connection.
Deburr the holes using a suitable tool.
Remove the drilling residues from the inverter.
Switch off the automatic circuit breaker
and DC disconnector.
Make sure that the DC disconnector is in
the "Off" switch setting.
Loosen the five screws of the connection
area cover by rotating them 180° to the left
using a screwdriver (TX20).
Remove the connection area cover from
the device.