Technical data

Fronius Primo GEN24
DC input data
MPP voltage range
(at nominal output)
Max. input voltage
at 1000 W/m²/-10 °C in an open circuit
Min. input voltage
Feed-in start voltage
Feed-in start voltage in grid operation
5)
Max. input current (PV1 / PV2)
Max. short circuit current of solar modules (I
3)
Max. backfeed current
Number of inputs - PV1
Number of inputs - PV2
DC input data battery
Max. voltage
Min. voltage
Max. current
Max. output
DC inputs
DC overvoltage category
(in accordance with IEC 62109-1)
AC input/output data
Nominal output power (P
Max. output power
Nominal grid voltage
Min. grid voltage
Max. grid voltage
Max. output current
6)
Starting current
Nominal frequency
Nominal frequency for Full Backup
Total harmonic distortion
2)
Power factor cos phi
)
SC PV
)
nom
3.0 / 3.0 Plus
3.6 / 3.6 Plus
190 - 530 V
200 - 530 V
600 V
65 V
80 V
80 V
22.0 / 12.0 A
33 / 18 A
33 / 18 A
2
2
455 V
150 V
22 A
3000 W
3680 W
1
2
3000 W
3680 W
3000 W
3680 W
1 ~ NPE 220V / 230V / 240 V
155 V
270 V
19.4 A
23.7 A
20 A / 1.3 ms
50 / 60 Hz
53 / 63 Hz
< 3.5%
0.8-1 (adjustable)
4.0 / 4.0 Plus
210 - 530 V
4000 W
4000 W
4000 W
1)
1)
25.8 A
1)
1)
137