General
Quick-lock sys-
tem
NOTE!
Danger when using a drill driver.
This may result in the destruction of the quick-lock system due to overtorque.
▶
▶
Warning notices
Technical data, warning notices and safety symbols are affixed to the inverter. These
on the device
warning notices and safety symbols must not be removed or painted over. They warn
against incorrect operation which can lead to serious injury and property damage.
Symbols on the rating plate:
Use a screwdriver (TX20).
Do not turn the screws more than 180°.
The devices comply with all the requisite and relevant standards and
guidelines that form part of the relevant EU Directive, and are therefore permit-
ted to display the CE mark.
A quick-lock system (3) is used to mount
the connection area cover and front cover.
The system is opened and closed with a
half-rotation (180°) of the captive screw (1)
into the quick-lock spring (2).
The system is independent of torque.
45