Modbus 0 (MB0) switch
Modbus 1 (MB1) switch
LAN 1
LAN 2
WSD terminal
USB
IOs terminal
Internal schem-
On the V+/GND pin, it is possible to feed in a voltage of around 12.5 - 24 V (+ max. 20%)
atic connection
with an external power supply. The outputs IO 0 - 5 can then be operated with the
diagram of the
external voltage. A maximum of 1 A can be drawn per output, with a maximum of 3 A
IOs
allowed in total. The fuse protection must be located externally.
Optical sensor
Communication LED
Operating status LED
Switches the terminating resistor for
Modbus 0 (MB0) on/off.
Position 1: Terminating resistor on
(factory setting)
Position 0: Terminating resistor off
Switches the terminating resistor for
Modbus 1 (MB1) on/off.
Position 1: Terminating resistor on
(factory setting)
Position 0: Terminating resistor off
To operate the inverter. See chapter
Button functions and LED status
indicator
on page 87.
Indicates the inverter connection status.
Indicates the inverter operating status.
Ethernet connection for data communic-
ation (e.g. WLAN router, home network
or for commissioning with a laptop, see
chapter
Installation using the web
browser
on page 89).
Ethernet connection only for data com-
munication from inverter to inverter (cur-
rently unavailable).
Push-in terminal for the WSD installa-
tion. See chapter
WSD (wired shut-
down)
on page 25.
Power supply max. 1 A at 5 V. Software
updates and data recording via USB is
not possible.
Push-in terminal for digital inputs/
outputs. See chapter
Permitted cables
for the data communication area
page 55.
The designations (RG0, CL0, 1/5, 2/6,
3/7, 4/8) on the terminal refer to the
Demand Response Mode function, see
chapter
Functions andI/Os
94.
on
on page
29