Alarm No
007 001
Web diameter was not detected
correctly
007 002
Web waste feed too slow
007 003
Web nonwoven feed too slow
007 004
Web PET feed too slow
007 005
Web waste feed too fast
007 006
Web nonwoven feed too fast
007 007
Web PET feed too fast
007 008
Web waste roll is full
007 009
Web nonwoven roll is near empty
007 010
Web PET roll is near empty
007 011
Web needs service, please check
before restarting process
007 012
WEB NW, drive error
007 013
Motor could not move as expected.
007 014
007 015
Drive power failure.
007 016
007 017
WEB PET, drive error
007 018
Motor could not move as expected.
007 019
007 020
007 021
Operation Manual|Cyrel FAST 2000TD
Description
Remedy
Web diameter could not be detected, please check
for empty supply rolls, broken web materials and if
machine is threaded correctly.
Web waste rotation too slow, please check for
empty supply rolls, broken web materials and if
machine is threaded correctly.
Web NW rotation too slow, please check for empty
supply rolls, broken web materials and if machine is
threaded correctly.
Web PET rotation too slow, please check for empty
supply rolls, broken web materials and if machine is
threaded correctly.
Web Waste rotation too fast, please check for
empty supply rolls, broken web materials and if
machine is threaded correctly.
Web NW rotation too fast, please check for empty
supply rolls, broken web materials and if machine is
threaded correctly.
Web PET rotation too fast, please check for empty
supply rolls, broken web materials and if machine is
threaded correctly.
Web Waste roll is full, please change.
Web NW roll is empty, please change.
Web PET roll is empty, please change.
Web NW, PET or Waste roll diameter has exceeted
the alarm limits during process. Please change web
rolls before restarting the process.
Check for jammed plates and mechanical failures
before initializing.
If the problem persists, please call an authorized
Service Technician.
Check the safety circuit and the machine power
supply before initializing.
If the problem persists, please call an authorized
Service Technician.
Check for jammed plates and mechanical failures
before initializing.
If the problem persists, please call an authorized
Service Technician.