25. Lock the chuck bearings in left and right side
by pressing the chuck bearings inwards
(towards the roll).
26. Mount one long piece of the double-sided self-adhesive tape down the entire length of the new roll
(1).
NOTE: The heat resistant tape Tesa 4965 (50 mm /2") is recommended.
27. Remove the protection paper from the double-side tape.
28. Detach the end of the old material (attached to the roll above) and mount it on top of the double-sided
tape (2). Make sure that the two layers of material are parallel.