AgaMatrix iBGStar Owner's Manual page 45

Table of Contents

Advertisement

This device has been tested and found to be in compliance
with FCC Part 15, Subpart B. These limits are designed to
provide reasonable protection against harmful interference
when the equipment is operated in a commercial
environment. This product generates, uses, and can radiate
radio frequency energy, which may cause interference to
other equipment. If in doubt about possible interference to
other equipment, please contact your distributor for support.
Guidance and manufacturer's declaration – electromagnetic emissions
The Model iBGSTAR is intended for use in the electromagnetic environment specified
below. The customer or the user of the Model iBGSTAR should assure that it is used in
such an environment.
Emissions test
Compliance
RF emissions
Group 1
CISPR 11
RF emissions
Class B
CISPR 11
Harmonic emissions
Class A
IEC 61000-3-2
Voltage fluctuations/
Complies
flicker emissions
IEC 61000-3-3
86
Electromagnetic environment – guidance
The Model iBGSTAR uses RF energy only
for its internal function. Therefore, its RF
emissions are very low and are not likely to
cause any interference in nearby electronic
equipment.
The Model iBGSTAR is suitable for use in
all establishments, including domestic
establishments and those directly
connected to the public low-voltage power
supply network that supplies buildings used
for domestic purposes.
Guidance and manufacturer's declaration – electromagnetic immunity
The Model iBGSTAR Image Intensifier is intended for use in the electromagnetic
environment specified below. The customer or the user of the Model iBGSTAR Image
Intensifier should assure that it is used in such an environment.
IMMUNITY
IEC 60601 test
Compliance
test
level
level
Electrostatic
± 6 kV contact
± 6 kV contact
discharge
± 8 kV air
± 8 kV air
(ESD)
IEC 61000-4-2
Electrical fast
± 2 kV for power
± 2 kV for power
transient/
supply lines
supply lines
burst
± 1 kV for input/
± 1 kV for input/
IEC 61000-4-4
output lines
output lines
Surge
± 1 kV line(s) to
± 1 kV
IEC 61000-4-5
line(s)
differential mode
± 2 kV line(s) to
± 2 kV common
earth
mode
IEC 61000-4-11
<5 % U
5 % U
T
Voltage
(>95 % dip in U
)
(>95 % dip in U
T
dips, short
for 0,5 cycle
for 0,5 cycle
interruptions
40 % U
40 % U
T
and voltage
(60 % dip in U
)
(60 % dip in U
T
variations on
for 5 cycles
for 5 cycles
power supply
70 % U
70 % U
T
input lines
(30 % dip in U
)
(30 % dip in U
T
for 25 cycles
for 25 cycles
<5 % U
<5 % U
T
(>95 % dip in U
)
(>95 % dip in U
T
for 5 s
for 5 s
3 A/m
3 A/m
Power
frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
NOTE U
is the a.c. mains voltage prior to application of the test level.
T
Electromagnetic
environment – guidance
Floors should be wood,
concrete or ceramic tile. If floors
are covered with synthetic
material, the relative humidity
should be at least 30 %.
Mains power quality
should be that of a typical
commercial or hospital
environment.
Mains power quality
should be that of a typical
commercial or hospital
environment.
Mains power quality should
T
)
be that of a typical commercial
T
or hospital environment. If
the user of the Model iBGSTAR
T
)
image intensifier requires
T
continued operation during
power mains interruptions,
T
)
it is recommended that
T
the Model iBGSTAR Image
Intensifier be powered from an
T
uninterruptible power supply
)
T
or a battery.
If image distortion occurs, it
may be necessary to position
the Model iBGSTAR image
intensifier further from sources
of power frequency magnetic
fields or to install magnetic
shielding. The power frequency
magnetic field should be
measured in the intended
installation location to assure
that it is sufficiently low.
87