Aeraulic Connection; Accessories Assembly - ViM JBRB ECOWATT PR Instruction Manual

Collective residential building controlled mechanical ventilation
Table of Contents

Advertisement

3.5 Accessories assembly

Circular connection to discharge
Fasten the sealed flat bracket using 6 self-drilling screws (not supplied).
For a unit not connected to discharge, add a vent cowl (CP) to enable 360° exhaust air outlet around
the vertical discharge axis. According to the NF DTU 68.3 P 1-1-1 standard, the CP makes it possible to
eliminate the effects of the wind and not add 20Pa of additional pressure drop.
4.

AERAULIC CONNECTION

En ligne
En ligne
En ligne
L
L
The unit must be fastened to a very flat surface, using the holes drilled in the mounting feet or the omega
Orientation
bars provided for this purpose. Mounting on anti-vibration supports and connection with flexible connectors
rejet
are recommended.
horizontal
L
Orientation
Orientation
En ligne
In-line
En ligne
En ligne
Orientation
rejet
rejet
L
rejet
horizontal
horizontal
horizontal
Horizontal
discharge
Orientation
Orientation
Orientation
rejet
rejet
Orientation
rejet
horizontal
horizontal
rejet
horizontal
vertical
Vertical
discharge
Orientation
Orientation
Orientation
rejet
rejet
rejet
vertical
vertical
vertical
The setup of this unit's aeraulic system and its network must meet the technical conditions defined in the
NF DTU 68-3 standard in case of installation of collective controlled mechanical ventilation.
Connection diameters:
Orientation
Orientation
rejet
rejet
Orientation
Model
vertical
vertical
rejet
JBRB ECOWATT
PR 04
®
vertical
JBRB ECOWATT
PR 06
®
JBRB ECOWATT
PR 10
®
JBRB ECOWATT
PR 22
®
JBRB ECOWATT
PR 30
®
JBRB ECOWATT
PR 38
®
JBRB ECOWATT
PR 48
®
JBRB ECOWATT
PR 70
®
JBRB ECOWATT
PR 82
®
JBRB ECOWATT
PR 92
®
En ligne
L
Modulable coudé à 90° /
Modulable coudé à 90° /
Modulable coudé à 90° /
double aspiration à 90°
double aspiration à 90°
double aspiration à 90°
En ligne
En ligne
L
L
L
Modulable coudé à 90° /
Modulable coudé à 90° /
Modulable coudé à 90° /
double aspiration à 90°
double aspiration à 90°
double aspiration à 90°
Orientation
90° elbow
Orientation
L
L
rejet
rejet
horizontal
horizontal
Orientation
rejet
horizontal
Orientation
Orientation
rejet
rejet
vertical
vertical
Orientation
rejet
vertical
L, M, D discharge
160
200
250
355
400
500
560
630
710
710
Modulable coudé à 90° /
double aspiration à 90°
Modulable coudé à 90° /
Modulable coudé à 90° /
M
M
double aspiration à 90°
double aspiration à 90°
M
M
Modulable coudé à 90° /
Modular
double aspiration à 90°
M
90° double inlet
En ligne
M
M
L
L, M inlet
160
200
250
355
400
500
560
630
710
710
15/48
M
Double aspiration
Double aspiration
Double aspiration
D
D
D
M
M
Double aspiration
Double aspiration
Double aspiration
D
D
D
M
NT00000603-JBRB-ECOWATT-PR-AN-191202
Double aspiration
D
Double aspiration
Double aspiration
D
D
D
Double inlet
Double aspiration
D
D inlet
-
-
200
315
-
400
450
-
560
560

Advertisement

Table of Contents
loading

Table of Contents