13

Technical data

Description
Mains voltage [V]
Rated current [A]
Grid frequency [Hz]
Network types
EMC class
Overvoltage category
Protection class
IP-protection class
Protection against mechanical im-
pact
Protective devices
Fixation type
Cable feed
Power supply conductor cross sec-
tion
Charging cable with charging
coupling
Mains connection terminal
Output voltage [V]
Max. charging power [kW]
Operating temperature range [°C]
Storage temperature range [°C]
Display
Lock
Altitude [m]
Permissible relative humidity [%]
Weight [kg]
Dimensions [mm]
II Webasto Pure EN
Data
230 / 400 AC (Europe)
16 or 32 (single phase or 3-phase)
50
TT / TN
Emitted interference: class B (residential, business, commercial areas)
Immunity: industrial areas
III as per EN 60664
I
IP54
IK08
A residual current circuit breaker and line circuit breaker must be provided on the installation
side. See chapter 7, "Installation and electrical connection" on page 5.
Wall and base mounting (permanently connected)
Mounted on-wall or in-wall
Depending on the cable and type of installation, the minimum cable cross-section for a stand-
ard installation is:
6 mm² (for 16 A)
10 mm² (for 32 A)
Type 2 according to EN 62196-1 and EN 62196-2
Connection cable:
n rigid (min.-max.) 2.5-10 mm²
n flexible (min.-max.) 2.5-10 mm²
n flexible (min.-max.) with wire end ferrule 2.5-10 mm²
230 / 400 AC
11 kW or 22 kW (depending on factory configuration)
-25 to +55 (without direct solar radiation)
-25 to +80
LED element
Key-operated switch set to start charging
max. 2000 (above sea level)
5 up to 95 Non-condensing
11 kW: 4.6
22 kW: 5.6
See figures in chapter 12, "Assembly" on page 10
Technical data | 13