Tab. 6:
Cylinders
3 Product description
3.1.2 KESO Genie EX-BS
EC type examination certificate
EX test certificate no.:
Ex marking in accordance with ATEX directive:
Cylinders
Permissible ambient conditions
Place of use, in accordance with equipment category
2G of the ATEX product guideline
Degree of protection, according to DIN EN 60529
Pressure
Ignition protection certified according to ignition
protection type ib of the ATEX product directive
Ignition energy for hydrogen, certified in accordance
with equipment group IIC of the ATEX product
directive
Surface temperature equipment, certified according
to temperature class instrument T4 of the ATEX
product directive
Temperature certified according to
IEC 60068-2-1/2/3/14
Relative humidity certified
according to IEC 60068-2-1/2/3/14
Electromagnetic compatibility
Lower and upper explosion limit
Radiated energy, vibrations and ultrasound
Types of ignition sources
IBExU07ATEX1030
II 2G Ex ib IIC T4
· In all industries except mining
· If explosive atmosphere occurs occasionally
during normal operation
IP54
Intrinsic safety: Energy limitation of sparks and
temperature
<60 μJ
135 °C maximum
-20 to +40 °C
10% to 95% RH (non-condensing)