Outside Finish Installation (Non Cool Wall)-Mantel Clearances; Outside Finish Installation (Non Cool Wall)-Mantel Leg Clearances - Regency Fireplace Products Grandview G600EC-NG Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

Outside Finish Installation (Non Cool Wall)—Mantel Clearances
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the Diagram below.
Mantel Clearances
15
10
17" (432 mm)
20
12" (305 mm)
15
B
10
C
5
0
Inches
A
To Floor
Mantel Clearances
G600EC
From Top of Fireplace
30" (762mm)
Note: Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour.
**The non combustible board supplied with the appliance is 13" (330 mm) high. This may be cut to size if desired.
Outside Finish Installation (Non Cool Wall)—Mantel Leg Clearances
5
Combustible
5" (127 mm)
D
Top of
Fireplace
A
B
19-1/2" (495mm)
TopView
Side opening
of fireplace
32" (813 mm)
Overall Fireplace Width (Outside Finish)
Non-Combustible Material
Min. 10 1/2" H (267mm)
C
15-3/4" (400mm)
10-1/2" (267mm)
1-1/2"
4-1/4"
(108mm)
6-7/8" (175mm)
Allowable mantel leg projection
D
Grandview® G600EC Gas Fireplace
installation
|
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grandview g600ec-lp

Table of Contents