Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance
to the difference between the set point temperature and the actual room
temperatures. As the room temperature gets closer to the set point the
Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word
"SMART" appears to the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until
the desired set temperature is displayed on the LCD screen of the
Transmitter (Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjust-
ment is disabled.
Figure 11: Smart Flame Function
Fan Speed Control**
If the appliance is equipped with a hot air circulating fan, the speed of
the fan can be controlled by the Proflame system. The fan speed can be
adjusted through six (6) speeds. To activate this function use the Mode
Key (fig.1) to index to the fan control icon (Fig. 13). Use the Up/Down
Arrow Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A single
"beep" will confirm reception of the command.
Figure 13
Figure 12
Figure 14
owner's information
Remote Dimmer Control (Bottom Ember Lights)
The bottom ember lights are located near the dimmable light control. To
activate this function use the Mode Key (fig. 1) to index to light bulb (fig.
15 & 16).
The intensity of the output can be adjusted through six (6) levels. Use
the Up/Down Arrow Keys (Fig.1) adjust the output level (Fig. 16). A single
"beep" will confirm reception of the command.
Note: This function is available only with the IFC Control Module.
Figure 15
Remote top light control (top light)
The auxiliary function controls the top light. To activate this function use
the Mode Key (fig. 1) to index to the AUX icon (fig. 17 & 18).
Pressing the Up Arrow Key will activate the outlet. Pressing the Down
Arrow Key will turn the outlet off. A single "beep" will confirm the recep-
tion of the command.
Figure 17
Split Flow control*
(*Not available on this model)
The secondary burner is controlled by the split Flow. To activate this
function use the Mode Key (fig. 1) to index to the SPLIT FLOW mode
icon (fig. 19 & 20).
Pressing the Up Arrow Key will activate the secondary burner. Pressing
the Down Arrow Key will turn the secondary burner off. A single "beep"
will confirm the reception of the command.
Figure 19
Grandview® G600EC Gas Fireplace
Figure 16
Figure 18
Figure 20
|
15