Fan Install After Unit Installation - Regency Fireplace Products Grandview G600EC-NG Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

installation

FAN INSTALL AFTER UNIT INSTALLATION

Fan Install After Unit Installation
1. The fan may be installed after the unit has been installed and finished.
Ensure the unit is turned off and has cooled to room temperature.
2. Shut off the power and gas to the unit.
3. Remove the screen and glass door. (See sections: Safety screen
removal / Installation & glass door removal / Installation)
4. Remove any media already installed (logs, glass, etc.) and set aside.
5. Remove the log grate.
6. Remove the burner.
7. Remove the firebox floor panel (brick or enamel).
8. Remove 12 screws from the firebox floor access panel as shown.
9. Lift out valve tray and set aside.
10. Connect the fan to the IFC and ground (follow Steps 4 -6 from the
previous page).
11. Push the IFC towards the front of the unit to make room for fan
install. Install fan assembly onto 2 pins on unit floor located in the
rear right section of the unit.
80
|
Grandview® G600EC Gas Fireplace
920-300
12. Move the IFC back into place and reinstall the valve tray,
burner, firebox media, door and safety screen by reversing
steps 9-2.
TO REMOVE THE FAN
1. Shut the power off.
2. Follow steps 2-9, but reverse steps 10-11.
Note: The bearings are lubricated for life. Do not lubri-
cate them. Make sure you vacuum the fan area
on a regular basis.
IMPORTANT:
The fans collect a lot of dust from within your home,
Ensure you maintain these fan motors on a regular
basis by vacuuming out the fan blades and housing
using a soft brush nozzle.