4.1 - DIP-SWITCH ADJUSTMENT
DIP
ON
OFF
FUNCTION
Step-by-step command mode:
Open / Stop / Close / Stop
At every start pulse (wired or via
transmitter), the control unit performs an
action. Starts the motor if the automation
system is stopped, and stops it if it is
moving.
Step-by-step with automatic closing (time
1
set with the "Pause" knob).
The control unit only accepts commands
(either wired or via transmitter) for the
opening phase. Starts again from zero
with the set delay when the automation
system is open. With the automation in
the opening phase, it continues to open,
and with the system in the closing phase
it reopens fully.
The automatic re-closing function is
activated. The control unit automatically
closes the leaves after the time set
through the "PAUSE" knob (see
Paragraph 4.2)
2
The automatic re-closing function is
deactivated.
To close the leaves, therefore, a command
must be given (either wired or via
transmitter).
The safety devices connected to terminal
"Phototest" [3] are subject to a preventive
check before starting any movement.
3
The safety devices connected to terminal
"Phototest" [3] are constantly supplied.
Belt guide
4
Chain guide
4.2 - KNOB ADJUSTMENT
FORCE
Power: adjustment of motor power. Turning the knob clockwise
increases the motor's power and speed. To validate the
modification, it is necessary to programme the gate path.
OBSTACLE
Obstacle, sensitivity to obstacles: adjustment of the obstacle
detection function. Turning the knob clockwise increases the
drive time before obstacle detection (less sensitivity). Therefore, in
systems with particularly unfavorable mechani- cal conditions, it
is advisable to keep the drive time high. OBSTACLE is set at half
position (50%) as factory setup.
PAUSE
Pause time before automatic gate closing. Turning the knob
clockwise increases the pause time from 0 to 180 seconds.
NOTE: this knob is functional only when AUTO dip-switch is put
to ON.
m
Varying the "POWER" knob has no effect until the
stroke is reprogrammed (par. 6).
5 - TRASMITTER PROGRAMMING
m
If, at the start of the following procedures, the
"set", "radio" and "error" LEDs flash, it means that the
programming protections have been activated – see
Paragraph 14.1. Therefore, radio transmitters learning is not
possible
m
To interrupt the following programming procedures at
any time, press the RADIO button or wait 20 seconds.
5.1 - START BUTTON PROGRAMMING
This procedure allows for programming the button of the radio
control linked to the automation's start function:
1. PRESS THE RADIO BUTTON FOR 1 SECOND: The red "radio"
LED turns on in the fixed mode (if not, consult Paragraph
14.1)
2. PRESS THE DESIRED BUTTON ON EVERY TRANSMITTER TO BE
PROGRAMMED: The red "radio" LED flashes
3. PRESS THE RADIO BUTTON UNTIL RADIO LED TURNS OFF OR
WAIT 20 SECONDS TO EXIT THE PROCEDURE: The red "radio"
LED turns off