Software Type_Id For Modules - Honeywell NOTIFIER AM-8200 Programming Manual

Fire detection panel
Hide thumbs Also See for NOTIFIER AM-8200:
Table of Contents

Advertisement

Input modules for CONTACTS 
TABLE‐1 
Input Module 3 Treshold EN54 
MON3 
Input Module  2 Treshold (NOT EN 54 compliant) 
MON 
Same as MON, but label "MANUAL Call Point". 
PULL 
Input Module Non Alarm 
NONA 
Input Module same as NONA, signal both status variation 
STAT 
Input Module for N.C. contacts 
NCMN 
Input Module Tamper. 
MTRB 
Input Module for remote  ACK (pulse). 
MACK 
Input Module for remote  SILENCE (pulse). 
MTAC 
Input Module  for remote  RESET  (pulse). 
MRES 
Input Module  conventional zone 
SCON 
Output Modules  Supervised Output Advanced and VDS 
TABLE ‐2 
Output Module  supervised  
CON 
Output Module supervised VDS 
CONV 
Output Module – Relay output contacts free voltage. 
FORC 
Output Module FORC interrupts momentarily the power supply (used for reset 
PWRC 
conventional detectors) 
Output Module FORC activated at each alarm / fault. 
GPND 
Output Module FORC activated at each alarm. 
APND 
Output Module FORC activated at each alarm.  
GAC 
Output Module CON activated at each alarm. 
GAS 
Same as GAS but with controlled VDS output 
GASV 
Output Module FORC activated at each fault. 
TPND 
Output Module FORC activated at each fault. 
GTC 
Output Module CON activated at each fault. 
GTS 
Same as GTS but with controlled VDS output 
GTSV 
Output Module FORC activated at each fault. 
TRS 
Output Module activated in case of exclusion of point or zone. 
ZDIS 
Output Module (not supervised) activated for Power Failure. 
MAINF 
Come MANIF, supervised 
MAINFC 
Come MANIF, ma con uscita supervisionata (EOL RES complies VdS) 
MAINFV 
Output Module con contatti liberi da potenziale, comandabile solo da supervisione 
REM 
Same as REM supervised 
REMC 
Same as REM, supervised (EOL RES complies VdS) 
REMV 
SND 
Output Module which follows the status of the panel Sounder Output 
Output Module FORC activated when the associated zone is in fault 
ZFLT 
come ZFLT supervised 
ZFLTC 
come ZFLT supervised VdS 
ZFLTV 
Output Modules  Supervised Output Advanced and NOT VDS 
TABLE ‐2B 
Output Module supervised Output 
CON 
Output Module relay with potential‐free contacts. 
FORC 
Output Module FORC interrupts momentarily the power supply  
PWRC 
Output Module FORC activated at every alarm / fault. 
GPND 
Output Module FORC activated at every alarm. 
APND 
Output Module FORC activated at every alarm. 
GAC 
Output Module CON activated at every alarm. 
GAS 
Output Module FORC activated at every fault.. 
TPND 
Output Module FORC activated at every fault.. 
GTC 
Output Module CON activated at every fault..  
GTS 
Output Module FORC activated at every fault.. 
TRS 
Output Module activated in case of exclusion of point or zone. 
ZDIS 
PAGE - 70
NOTIFIER ITALIA
Appendix B : Software Type_ID for MODULES
Programming Manual
Doc. M-162.1-AM8200-ENG Rev A2
CBE Y/N 
CBE Y/N 
CBE Y/N 
AM_8200
AM8200_manu-prog-ENG