X141, Safety Technology (Kmv03); Second Equipment Grounding Conductor Connection Point - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

200/407
Connection points
6.6.5

X141, safety technology (KMV03)

View
Female connector M12 (12‑pin,
D‑coded)
Ready-made connection cable
Function
Channel 1 selection
Channel 2 selection
6.6.6

Second equipment grounding conductor connection point

Bosch Rexroth AG R911335703_Edition 04
A KMV03 distributed supply unit never is a node of a safety zone.
However, the signals for a following "Safe Torque Off" safety
zone can be input at KMV03 via X141.
Connecti
Signal name
Function
on
1
SI_Ch1
Input for selection of channel 1 (connected to X103.2.10)
2
SI_Ch2
Input for selection of channel 2 (connected to X103.2.8)
3
n.c.
-
4
n.c.
-
5
n.c.
-
6
n.c.
-
7
n.c.
-
8
n.c.
-
9
n.c.
-
10
0V
Inputs and outputs power supply (connected to X103.2.9)
11
n.c.
-
12
n.c.
-
RKB0033
Can be used to input the signals for "Safe Torque Off" safety technology.
Tab. 6-53:
Function, pin assignment, properties
Technical data
Signal
SI_Ch1
SI_Ch2
Tab. 6-54:
Technical data
See
chapter 6.3.8
"Second connection point of equipment grounding
conductor" on page 178
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Connection
Technical data
1
chapter 14.1.2 "Digital inputs (safety
technology L options)" on page 369
2

Advertisement

Table of Contents
loading