Has02, Shield Connection - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

302/407
Accessories
10.3

HAS02, shield connection

Bosch Rexroth AG R911335703_Edition 04
For proper and correct installation of KSM and KCU, use the RKH
hybrid cable and the HAS02.1-015-NNN-NN accessory.
The HAS02.1-015-NNN-NN accessory connects the shield of the hybrid
cable to the housing of the KCU drive connection box.
1
Shielding plate
2
Clip
3
Hybrid cable
4
Shield of hybrid cable
Fig. 10-1:
Shield connection
Mount the shielding plate (1) to the drive connection box KCU according
to the desired outgoing direction of the hybrid cable (horizontal or 45°).
According to the diameter of the hybrid cable (3), the shielding plate (1)
provides two supports (12–18 mm or 19–30 mm). Fix the hybrid
cable (3) to the corresponding support with a clip (2). Make sure that the
shield (4) of the hybrid cable has good contact with the shielding
plate (1).
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03