IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
4.2
Transport and storage
4.2.1
Transporting the components
Description
Temperature range
Relative humidity
Absolute humidity
Climatic category (IEC 721)
Moisture condensation
Icing
4.2.2
Storing the components
CNCA is the Chinese authority responsible for certification guidelines. When
a product is imported in China, the certification will be checked at customs
using the entries in a database. Three criteria are typically critical for
certification being required:
1.
Customs tariff number (HS code) according to CNCA document
"Application Scope for Compulsory Certification of Products acc. first
Catalogue".
2.
Area of application according to CNCA document "Application Scope for
Compulsory Certification of Products acc. first Catalogue".
3.
For the IEC product standard used, a corresponding Chinese
GB‑standard must exist.
For the drive components by Rexroth described in this documentation,
certification is currently not required, so they are not CCC certified. Negative
certifications will not be issued.
Ambient and operating conditions for transport
Symbol
Unit
T
°C
a_tran
%
g/m
3
Tab. 4-4:
Ambient and operating conditions for transport
NOTICE
The KCU drive connection box contains electrolytic capacitors which may
deteriorate during storage. When storing the KCU drive connection box for a
longer period of time, run it once a year for at least 1 hour at 24 V control
voltage U
.
N3
NOTICE
The KMV supply unit contains electrolytic capacitors which may deteriorate
during storage. When storing the KMV supply unit for a longer period of time,
run it once a year for at least 1 hour at mains voltage U
General data and specifications
Value
-20 ... +70
5 ... 95
1 ... 60
2K3
Not allowed
Not allowed
KCU drive connection
Risk of damage to the
box from long-term storage!
KMV supply unit from
Risk of damage to the
long-term storage!
.
LN
R911335703_Edition 04 Bosch Rexroth AG
47/407