Connecting The Communication Cable - Siemens VersiCharge Operating Instructions Manual

Wallbox ac
Table of Contents

Advertisement

4.8

Connecting the communication cable

Connection of the communication cables
Proceed as follows to connect the communication cables for Ethernet or Modbus:
Note
Connect the plugs after insertion
Only mount the RJ45 plug or Modbus RTU plug after insertion through the sealing insert.
Mounting the plug before insertion results in damage to the sealing insert.
1. Guide the communication cables for Ethernet or Modbus through the wall bracket.
2. Make a small hole in the sealing insert using a small screwdriver, for example.
3. Guide the cables through the sealing insert at the bottom of the device into the Wallbox.
4. Mount the required plug-in connectors. Observe the specifications of the connector
manufacturer.
5. Insert the necessary connectors into the corresponding socket on the board.
VersiCharge AC Wallbox IEC
Operating Instructions, 03/2021, A5E50366109-AA
Mounting / Installing / Connecting
4.8 Connecting the communication cable
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents