3. Temporarily clamp the Wallbox into the recesses at the top and bottom of the rear cover
plate. This important step requires the highest possible care for further mounting of
Wallbox and column.
4.6

Connecting the supply cable

1. Route the cable through the opening in the column and through the screw gland of the
VersiCharge.
2. Route the cable through the cable gland and connect each wire to the marked or
corresponding connection point on the terminal block. Observe the following sequence
when connecting the wire (from left to right): Connect the green-yellow wire first, and
then the remaining wires one after the other by matching the numbers on the terminal
block and wire.
VersiCharge Column Mounting
Hardware Installation Manual, 06/2022, A5E51460654-AB
Recesses are provided for temporary support of the Wallbox on the cover plate.
Hose connection on the Wallbox for connection
Mounting / Installing / Connecting
4.6 Connecting the supply cable
29