Parameter Setting Of Speed Axis; Connections - Optimum OPTImill BF 20V Operating Manual

Drilling-milling machine
Hide thumbs Also See for OPTImill BF 20V:
Table of Contents

Advertisement

OPTIMUM
M A S C H I N E N - G E R M A N Y
5.4.4

Parameter setting of speed axis

Teeth amount of every turn (pulses per rev)
Press the "PROG" key to enter the menu, selection range is 1~36, the increment or decrement is 1.
Display mode
Press the "PROG" key to enter the menu. "On / Off" as a select.
Save and Exit
Saving new parameters, press the "PROG" key to confirm, then return to section 5.4.2
5.5

Connections

Connection power supply
21V ~ 27V DC / 0.5 amps
Working temperature
Storage temperature
Humidity
Protection type
Electrical data
Power supply
Mains connection
Current consumption
Mains connection
System data, resolution and accuracy:
Magnetic sensors
Resolution [mm]
Travel speed max.
GB
BF20LD
Page 42
®
Connection
Speed measurement
Connections
Magnetic sensors
Plug type MINI-DIN
(6-pins)
0 °C ... +50 °C
-10 °C ... +60 °C
max. 80 %rF
IP50
21 V to 27 V DC
~ 500 mA
MS100, MS200, MS500
ǀ
ǀ
ǀ
0.001
0.002
0.005
0.01
0.05
5 m/s