4-5. ADA-61 Board (BKMA-513) Adjustment

4-5-4. Preparation before Video Adjustment

Notes
Check the following setup menus before starting adjustment.
. Check the NTSC/PAL setup. (Refer to menu No. 010 of the MAV-555A Installation Manual.)
. Check the network setup. (Refer to menu No. 220 of the MAV-555A Installation Manual.)
Connection
Signal generator
RAMP
or
Color bar
Black burst
Ethernet
PC
n
Ethernet is a registered trademark of Xerox Co., Ltd.
Setting
1. Set "1in/3out" using the setup menu "42-PORT CONFIG".
n
For the operating procedure, refer to the Operation Manual of the MAV-555A.
2. Open "782-INT VD SG R1" of the setup menu.
3. Set the setup menu "704-OUT SETUP P1" or "705-OUT SETUP P2" or "706-OUT SETUP P3" to
"off". (Refer to the Installation Manual of the MAV-555A.)
n
For the operating procedure, refer to the Installation Manual of the MAV-555A.
4. Turn the main power off and back on. Restart the MAV-555A.
n
To restart the MAV-555A quickly, execute "027-FAST REBOOT" of the setup menu.
5. Press the R1 button on the PORT SELECT block of the meter panel.
(Set so that the internal SG is output to the R1 port.)
6. Press the COMPOSITE button of the VIDEO INPUT SELECT block of the meter panel for at least
three seconds. (The internal SG starts, and the COMPOSITE button and the SDI button are turned
on.)
7. Press either the P1 button of the PORT SELECT block of the meter panel.
8. Press the CONTROL button of the VIDEO PROCESS block on the meter panel several times, and
enter the LOCAL mode.
4-12 (E)
MAV-555A + BKMA-513
VIDEO IN
VIDEO OUT
(COMPOSITE)
P1-A,
R1-IN
P2-A
or
or
R2-IN
P3-A
REFERENCE
ETHER
IN
Waveform monitor
or
Oscilloscope
MAV-555A

Advertisement