2-3. Removing/Reattaching the
360d d d d d Camera Module
Removal
1. Remove the lower cover.
(Refer to Section 1-2-2.)
2. Remove the clear dome assembly.
(Refer to Section 1-2-3.)
3. Remove the two screws (K3 x 6), and
remove the camera case (lower).
4. Remove the three screws (P2.6 x 4), and
remove the camera stay cover.
5. Remove the screw (PSW3 x 8), and remove
the camera case (upper).
6. Remove the two screws (B2 x 4), and
remove the inner case.
7. Disconnect the harness from the three
connectors on the VISCA board.
8. Remove the four screws (B2 x 4), and
remove the VISCA board.
9. Disconnect the harness from the two connec-
tors of the 360d camera module.
10. Remove the two screws (B2 x 10), and
remove the DC fan.
11. Remove the two screws (P2.6 x 10), and
remove the 360d camera module.
Installation
12. Reattach the 360d camera module in the
reverse order of steps 3 to 11.
m
. When attaching the 360d camera module,
make sure to align the hole in the camera
stay to the positioning boss of the 360d
camera module.
. When attaching the DC fan, be sure to have
the right side and direction for the labels
and harness.
13. Reassemble the unit in the reverse order of
steps 1 and 2.
2-4 (E)
P2.6 x 4
PSW3 x 8
P2.6 x 4
Camera stay cover
Hole
Positioning boss
K3 x 6
Camera case (lower)
Camera stay
Camera case (upper)
PS2.6 x 10
B2 x 4
Inner case
360d camera module
K3 x 6
B2 x 4
VISCA
board
DC fan
B2 x 10
Label
XIS-10DC