Image processing
White balance
Contrast (tone) compensation
Contour processing (sharpness)
Hue adjustment
Saturation adjustment
RB (red and blue) adjustment
Black level
Special effect (color effect)
Settings that can be initialized (and initial
values)
Chapter 20
Main Specifications
Set by the user. Red and blue gain values can be adjusted.
7 settings: [WIDE D], [WEAK], [STANDARD], [STRONG], [LINEAR], [METAL],
[ENHANCE])
9 levels: -3 (soft) to +5 (sharp)
-50 to +50 (minimum step: 1)
-50 to +50 (minimum step: 1)
50 to 150 (minimum step: 1)
-50 to +50 (minimum step: 1)
3 types: [COLOR], [B&W], [NEGA]
[SCENE/CSM]
OFF
[EXP CMP]
0
[CAM GAIN]
Cleared (because exposure mode is set to program AE)
[IMG MODE]
FAST
[EXP MODE]
PROG
[MTR MODE]
AVERAGE
[MTR AREA]
LARGE
[AE LOCK]
OFF
[RB ADJUST]
100, 100
[CHROMA]
0
[HUE]
0
[EFFECT]
COLOR
[BK LEVEL]
0
[CONTRAST]
STANDARD
[SHARPNESS]
2