Operation Status Group - Agilent Technologies N3280A User Manual

Component test dc source
Table of Contents

Advertisement

5 - Programming the DC Source
Bit
Signal
Meaning

Operation Status Group

The selected output is in constant voltage mode (applies only in voltage priority mode)
0
CV
1
CL+
The selected output is in positive current limit (applies only in voltage priority mode)
2
CL-
The selected output is in negative current limit (applies only in voltage priority mode)
3
CC
The selected output is in constant current mode (applies only in current priority mode)
4
VL+
The selected output is in positive voltage limit (applies only in current priority mode)
5
VL-
The selected output is in negative voltage limit (applies only in current priority mode)
6
OFF
The selected output is OFF
Questionable Status Group
0
OV+
The positive overvoltage protection has tripped
1
OV-
The negative overvoltage protection has tripped
2
PCLR
No communication with the selected output
The overtemperature protection has tripped
4
OT
10
UNR
The output is unregulated
12
OSC
The oscillation protection has tripped
14
MeasOvld
Output measurement exceeded capability of the range
Standard Event Status Group
0
OPC
Operation complete
Query error
2
QYE
3
DDE
Device-dependent error
4
EXE
Execution error
5
CME
Command error
7
PON
Power-on
Status Byte and Service Request Enable Registers
2
WTG
The unit is waiting for a trigger
3
QUES
Questionable status summary bit
Message Available summary bit
4
MAV
5
ESB
Event Status Summary bit
6
MSS
Master Status Summary bit
Request Service bit
RQS
7
OPER
Operation status summary bit
Operation Status Group
The Operation Status registers record signals that occur during normal operation. As shown below, the
group consists of a Condition, PTR/NTR, Event, and Enable register. The outputs of the Operation Status
register group are logically-ORed into the OPERation summary bit (7) of the Status Byte register.
Register
Condition
STAT:OPER:COND? (@< channel list >)
PTR Filter
STAT:OPER:PTR <n> (@< channel list >)
NTR Filter
STAT:OPER:NTR <n> (@< channel list >)
Event
STAT:OPER:EVEN? (@< channel list >)
Enable
STAT:OPER:ENAB <n> (@< channel list >)
50
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 5-1. Bit Configurations of Status Registers
Command
Description
A register that holds real-time status of the circuits
being monitored. It is a read-only register.
A positive transition filter that functions as described
under STAT:OPER:NTR|PTR commands in chapter 6.
It is a read/write register.
A negative transition filter that functions as described
under STAT:OPER:NTR|PTR commands in chapter 6.
It is a read/write register.
A register that latches any condition that is passed
through the PTR or NTR filters. It is a read-only
register that is cleared when read.
A register that functions as a mask for enabling specific
bits from the Event register. It is a read/write register.

Advertisement