Scpi Programming Commands - At A Glance - Agilent Technologies N3280A User Manual

Component test dc source
Table of Contents

Advertisement

6 – Language Dictionary

SCPI Programming Commands - At a Glance

ABORt
CALibrate
:CURRent
[:LEVEL] (@channel)
:LIMit
[:POSitive] (@channel)
:NEGative (@channel)
:MEASure <max_val>, (@channel)
:DATA <n>
:DATE <date>
:LEVel <level>
:PASSword <n>
:SAVE
:STATE <bool> [,<n>]
:VOLTage (@channel)
INITiate
[:IMMediate]
:NAME <name>
FETCh
:ARRay
:CURRent [:DC]? (@list)
:VOLTage [:DC]? (@list)
[:SCALar]
:CURRent [:DC]? (@list)
:VOLTage [:DC]? (@list)
MEASure
:ARRay
:CURRent [:DC]? [max_val,] (@list)
:VOLTage [:DC]? (@list)
[:SCALar]
:CURRent [:DC]? [max_val,] (@list)
:VOLTage [:DC]? (@list)
OUTPut
[:STATe] <bool>, (@list)
:OSCProtect
[:STATe] <bool>, (@list)
:PROTection
:CLEar (@list)
SENSe
:CURRent[:DC]
:RANGe [:UPPer] <max_val>, (@list)
:FUNCtion <function>, (@list)
:SWEep
:NPLCycles <n>
:OFFSet
:POINts <n>
:POINts <n>
:TINTerval <n>
:WINDow [:TYPE] <type>
54
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 6-1. Subsystem Commands Syntax
Resets the trigger system to the Idle state
Calibrate output current and low current measurement range
Calibrate positive current limit
Calibrate negative current limit
Calibrate high and medium current measurement range
Enters the calibration value
Sets the calibration date
Advance to next calibration step (P1 | P2)
Set numeric calibration password
Save new cal constants in non-volatile memory
Enable or disable calibration mode
Calibrate output voltage and voltage measurement range
Enable the named trigger system (TRANsient | ACQuire)
Returns the digitized instantaneous current
Returns the digitized instantaneous voltage
Returns output current dc measurement
Returns output voltage dc measurement
Digitizes and returns the instantaneous output current
Digitizes and returns the instantaneous output voltage
Digitizes and returns average (dc) output current
Digitizes and returns average (dc) output voltage
Enables/disables the selected dc source output
Enables/disables oscillation protection on the selected output
Reset latched protection
Selects the current measurement range
Configures the measurement sensor (
Sets the number of ac power line cycles
Defines the trigger offset in the measurement sweep
Defines the number of data points in the measurement
Sets the measurement sample interval
Sets measurement window function
)
"VOLTage" | "CURRent"
(HANNing | RECTangular)

Advertisement