TRIGger:ACQuire:SOURce

This command selects the trigger source for the measurement trigger system.
EXT
External trigger input signal
GPIB device, *TRG, or <GET> (Group Execute Trigger)
BUS
Command Syntax TRIGger:ACQuire:SOURce <source>
Parameters
*RST Value BUS
Examples TRIG:ACQ:SOUR EXT
Query Syntax TRIGger:ACQuire:SOURce?
Returned Parameters <CRD>

TRIGger[:TRANsient]:SOURce

This command selects the trigger source for the output trigger system.
EXTernal
External trigger input signal
BUS
GPIB device, *TRG, or <GET> (Group Execute Trigger)
Command Syntax TRIGger[:TRANsient]:SOURce <source>
Parameters
*RST Value BUS
Examples TRIG:SOUR EXT
Query Syntax TRIGger[:TRANsient]:SOURce?
Returned Parameters <CRD>

TRIGger[:TRANsient]

This command generates an output trigger. Output triggers affect the following functions: voltage,
current, and current limit. To program an output trigger you must specify a trigger level for the selected
function, set the selected function to STEP mode, and initiate the trigger system.
Once these conditions are met, the output trigger will:
1. Initiate a pending level change as specified by [SOURce;]CURRent:TRIGgered,
[SOURce;]CURRent:LIMit:TRIGgered, or [SOURce;]VOLTage:TRIGgered.
2. Clear the WTG bit in the Status Operation Condition register after both transient and acquire trigger
sequences have completed. (WTG is the logical-or of both transient and acquire sequences.)
Command Syntax TRIGger[:TRANsient][:IMMediate]
Parameters None
Examples TRIG
Related Commands ABOR
74
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
BUS | EXTernal
BUS | EXTernal
TRIG:IMM
INIT
*TRG
CURR:LIM:TRIG
CURR:MODE
VOLT:MODE
VOLT:TRIG