Specifications
The following tables list specifications for the various IQ 7 Series models and for the Q Cable.
IQ7-60-2-INT Microinverter Specifications
Topic
Commonly used module pairings
Peak power tracking voltage
Operating voltage range
Maximum input DC voltage
Minimum / maximum start voltage
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum continuous AC output power (-40C to +65C)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
230 VAC (single phase)
Nominal output current
230 VAC (single phase)
Nominal frequency
Extended frequency range
Overvoltage class AC port
AC port backfeed under single fault
Power factor setting
No enforced DC/AC ratio. See the compatibility calculator at
1
Nominal Voltage Range can be extended if required by the utility.
2
28
IQ 7 / IQ 7+ / IQ 7X / IQ 7A Installation and Operation
Enphase IQ7-60-2-INT Microinverter Parameters
DC Parameters
1
AC Parameters
2
© 2020 Enphase Energy Inc. All rights reserved.
Unit
V
V
V
V
A
A
1x1 ungrounded array; No additional DC side protection
required; AC side protection requires max 20A per branch
VA
VA
Vrms
Arms
Hz
Hz
A
module-compatibility.
Min
Typical
235 W – 350+ W
27
16
22
II
circuit
240
250
0.8 leading
0.8 lagging
184
1.04
50
45
III
0
1.0
141-00044-02
Max
37
48
48
48
15
0
276
55