Maximum
microinverters per 20A (max) AC branch circuit
12
230 VAC (single phase)
EN 50530 (EU) weighted efficiency
230 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
12
.
35
IQ 7 / IQ 7+ / IQ 7X / IQ 7A Installation and Operation
IQ7X-96-2-INT Microinverter Parameters
Miscellaneous Parameters
Features and Specifications
Pairs with 96-cell PV modules
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 (or Amphenol H4 UTX with additional Q-DCC-5
adaptor)
1.08 kg
IP67 / outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
Power line
enphase.com/warranty
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-1,
IEC/EN 62109-2
The DC circuit meets the requirements for ungrounded PV
arrays. Ground fault protection (GFP) is integrated into the
class II double insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options
require an Enphase Envoy-S
The DC connector has been evaluated and approved for
use as the load-break disconnect.
The AC connector has been evaluated and approved for
use as the load-break disconnect.
© 2020 Enphase Energy Inc. All rights reserved.
%
96.5
%
99.5
%
C
-40
mW
C
-40
6 mm mounting hardware: 5 N m
8 mm mounting hardware: 9 N m
When using earthing hardware, use the manufacturer's
recommended torque value
12 (single-phase)
36 (multiphase)
5
+60
50
+85
141-00044-02

Hide quick links: