enphase IQ 7 Installation And Operation Manual page 33

Microinverters
Table of Contents

Advertisement

Maximum
microinverters per 20A (max) AC
9
branch circuit – 230 VAC
EN 50530 (EU) weighted efficiency
230 VAC (single phase)
Static MPPT efficiency (weighted, ref EN
50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
9
.
33
IQ 7 / IQ 7+ / IQ 7X / IQ 7A Installation and Operation
IQ7A-72-2-INT Microinverter Parameters
Miscellaneous Parameters
%
%
%
C
mW
C
Features and Specifications
Pairs with most 60 and 72-cell PV modules
212 mm x 175 mm x 30.2 mm (approximate)
Model IQ7A-72-2-INT: Bulkhead with MC4 locking type connector
1.08 kg (2.38 lbs.)
IP67 / outdoor
6 mm mounting hardware: 5 N m
8 mm mounting hardware: 9 N m
When using earthing hardware, use the manufacturer's
recommended torque value
Natural convection – no fans
4% to 100% condensing
Yes
PD3
Power line
enphase.com/warranty
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-1,
IEC/EN 62109-2, EN 50549, G98/G99, VDE-AR-N-4105
The DC circuit meets the requirements for ungrounded PV arrays.
Ground fault protection (GFP) is integrated into the class II double
insulated microinverter.
Enlighten Manager and MyEnlighten monitoring options require an
Enphase Envoy-S
The DC connector has been evaluated and approved for use as the
load-break disconnect.
The AC connector has been evaluated and approved for use as the
load-break disconnect.
© 2020 Enphase Energy Inc. All rights reserved.
11 (single-phase)
39 (multiphase, requires 25 A OCPD)
96.5
99.5
-40
-40
5
+60
50
+85
141-00044-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq 7+Iq 7xIq 7aIq7 seriesIq7plus-72-2-intIq7a-72-2-int

Table of Contents