Electrical Integration; Tab 3 Connector Pin-Out; Tab 4 Vehicle Power Electrical Transients - Baumer R600V.DAE0-11209335 Operating Manual

Off-highway ground & crop radar sensor
Hide thumbs Also See for R600V.DAE0-11209335:
Table of Contents

Advertisement

2.3 Electrical Integration

The sensor can be used on direct vehicle power for 12VDC nominal voltage systems, and
24VDC nominal voltage systems in the range +VS = 9VDC ... 32VDC. A centralized load
dump suppression (35V at 12VDC, and 58V at 24VDC nominal voltage respectively) is re-
quired. The product shall not be used in the direct control and modification of the state of
function of the machine. Please refer to the data sheet for information regarding operation
during the engine start phase, and further technical details. Prior to electrical connection of
the product the system must be down and not live. Do not exceed permissible bending radius
of the cable. The device shall be appropriately protected by an external R/C or fuse. In an
industrial environment the device shall be protected by an external R/C or listed fuse, rated
max. 100W/Vp or max. 5A below 20VDC, and a UL class 2 power supply be used.
Tab 3
Connector Pin-Out
Connection type
Ampseal 16 4P (776536-1)
Mating connector
Ampseal 16 4P (776524-1)
Pin
Code
Description
1
+Vs
Positive Supply voltage (12VDC /
24VDC nominal)
2
CAN HI
CAN High
3
GND
Ground (supply voltage)
4
CAN LO
CAN Low
This product may be used on vehicle power fulfilling these requirements:
Tab 4
Vehicle Power Electrical Transients
Test pulse (ISO 7637-2, ISO 16750-2)
Severity level
Functional status (12 VDC vehicle power)
Functional status (24 VDC vehicle power)
For test installations a cable with the order code 11213075 (ZCABL-ALL.AMP0300) may be
used.
CAUTION
The product shall not be used in the direct control and modification
of the state of function of the machine.
CAUTION
The product shall not be operated during engine start phase.
ATTENTION
The product shall not be used on machines without centralized load dump
suppression.
R600V.DAE0_manual_1.5 (EN).docm
Last Update: 07 Jan 2021
1
2a
2b
3a
3b
IV
III
IV
III
III
C
A
C
A
A
C
A
C
A
A
Manual R600V.DAE0 (EN)
4
5b
III
--
C
A
C
A
Page 15 of 29

Advertisement

Table of Contents
loading

Table of Contents