5.2.4
Technical data
Supply voltage UB:
Relay outputs direction A/B:
Temperature monitor:
Digital inputs, 1 psc.:
Accuracy:
Data stored using Li battery 1.2 Ah:
Temperature range:
Protective rating:
Housing:
Connection:
Danger from electric current or voltage!
Severe injuries up to death.
Before working on the electric installation, interrupt electric power sup-
ply and secure it against resetting.
Only a specialist may execute the electrical connection. The terminal
DANGER!
box may be opened only if there is no voltage.
5.2.5 LED display
LED
red on
green off
yellow off
red off
green on
yellow off
red off
green off
yellow on
red off
green on
yellow on
LED
red/green flashing
alternating with
yellow flashing
red/green/yellow
running light
red flashing
Further flashing combinations are explained under set-up mode.
Revision: 05
The temperature protection is active
The cylinder has been completely extended
The cylinder is completely retracted
The cylinder is in the normal working range
Error
Fault Actual value position
or
the battery is empty.
The board has not been adjusted correctly.
The magnet sensor is not in the centre of
the permanent magnet or there is too
much or too little distance between the
sensor and the magnet.
The board was expanded.
Incorrect lateral distance to the magnet is
detected when the motor axis revolves
5.2-3/11
24V DC +20 –30%
250V AC/5A, 30VDC/5A
on board
24V DC +20 – 30%
1%
10 years
-40°C to +85°C
IP00 (PCBs sealed)
Without
Plug-in screw-type terminals (Phoenix system)
Operating Status
Board mounting must be
Board mounting must be
.
Measure
New
parameterize
or
change Battery.
checked.
New parameterize
checked.
154-625-2

Hide quick links:

Advertisement

loading

This manual is also suitable for:

1190642-0010162-407-5