Gas installation

Tables of pressure and adjustments

only for: Australia and New Zealand.
Heat effect
Tumble
type
kW
21
300/30
500/50
40
750/75
57
487 18 39 01 - 300/500/750 - GB
Installation - gas heating
Gas type
Upper calorific
value
MJ/m3
Propane
126.4
GN
37.4
Propane
126.4
GN
37.4
Propane
126.4
GN
37.4
Gas pressure
Nozzle pressure
Inlet
(Measuring branch)
2
kPa
kPa
3
2.577
1.8
0.8
3
2.44
1.8
0.8
2.75
2.75
1.15
0.8
44.1
Ø
Nozzle
1
mm
2.4
4.0
3.5
5.6
3.8
6.5