Parameter Programming; Temperature Setting; Time Setting; Reversing - Electrolux TT300 Operating And Installation Manual

Table of Contents

Advertisement

48
Parameter no.
check by pressing
the clock button

Temperature setting

Temperature
program High
Temperature
program
Medium
Temperature-
program Low
Difference
between
heat
Temperature
on or off
hysteresis

Time setting

Running time
per pulse
(per coin insert -
or push
Time interval
if time-
controlled)
Max. running
time on manual
machine or
Max. running
running time per
time or
coin insert on
Time inter-
coin 2 (double
val,
insert)
coin 2

Reversing

Running time
between reversals

Parameter programming

Value
can be set after two seconds
The highest temperature
can be set to a value
between 32°C-85°C.
Factory setting = 85
The medium temperature
can be set to a value
between 32°C-85°C.
Factory setting = 70
Lowest temperature
can be set to a value
between 32°C-85°C.
Factory setting = 50
Can be set to a value
between 01°C-10°C.
Factory setting = 02
Can be set to a value
between 0.1 and 90 minutes.
Factory setting = 15
Can be set to a value
between 0.1 and 90 minutes.
Factory setting = 60
Can be set to a value
between 0.1 and 9,9 minutes.
Factory setting = 5.0
Required change:
Press the "count up/down" buttons.
Next para-
meter
Count down
From 0.1 to 9.9 minutes the setting can
be changed by increments of
1/10 minute per push.
From 10 to 90 minutes the setting can
be changed by increments of
1 minute per push.
From 0.1 to 9.9 minutes the setting can
be changed by increments of
1/10 minute per push.
From 10 to 90 minutes the setting can
be changed by increments of
1 minute per push.
Change the setting by
1/10 minute per push.
487 18 39 01 - 300/500/750 - GB
Count up

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tt500Tt750

Table of Contents