7.4 MODBUS MEMORY MAP
Table 7–6: MODBUS MEMORY MAP (SHEET 10 OF 27)
ADDR
DESCRIPTION
1177
Setpoint Group 4
S3
USER INPUT A
1180
User Input A Name (9 registers)
1189
User Input A Source
118A
User Input A Function
118B
User Input A Relays
118C
User Input A Delay
S3
USER INPUT B
1190
User Input B Name (9 registers)
1199
User Input B Source
119A
User Input B Function
119B
User Input B Relays
119C
User Input B Delay
S3
USER INPUT C
11A0
User Input C Name (9 registers)
11A9
User Input C Source
11AA
User Input C Function
11AB
User Input C Relays
11AC
User Input C Delay
S3
USER INPUT D
11B0
User Input D Name (9 registers)
11B9
User Input D Source
11BA
User Input D Function
11BB
User Input D Relays
11BC
User Input D Delay
S3
USER INPUT E
11C0
User Input E Name (9 registers)
11C9
User Input E Source
11CA
User Input E Function
11CB
User Input E Relays
11CC
User Input E Delay
S3
USER INPUT F
11D0
User Input F Name (9 registers)
11D9
User Input F Source
7
11DA
User Input F Function
11DB
User Input F Relays
11DC
User Input F Delay
S3
USER INPUT G
11E0
User Input G Name (9 registers)
11E9
User Input G Source
11EA
User Input G Function
11EB
User Input G Relays
11EC
User Input G Delay
S3
USER INPUT H
11F0
User Input H Name (9 registers)
11F9
User Input H Source
11FA
User Input H Function
11FB
User Input H Relays
11FC
User Input H Delay
S3
BLOCKING FUNCTIONS
1240
Block 1 TRIP Relay
1241
Block 2 CLOSE Relay
1242
Block Reset
1 2 3 4 5 6 7 8 9
For explanation of Table footnotes, see the Memory Map Notes at the end of this table.
7-22
Courtesy of NationalSwitchgear.com
RANGE
---
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
---
0.00 to 600.00
---
---
---
750/760 Feeder Management Relay
7 COMMUNICATIONS
UNITS
TYPE
DEFAULT
---
F65
Disabled
READ/WRITE
---
F33
User Input A
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input B
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input C
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input D
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input E
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input F
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input G
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F33
User Input H
---
F65
Disabled
---
F37
Disabled
---
F57
None
s
F3
0.00 s
READ/WRITE
---
F65
Disabled
---
F65
Disabled
---
F65
Disabled