6.5 A4 EVENT RECORDER
Table 6–3: CAUSE OF EVENTS
GENERAL EVENT CAUSES
Autoreclose Reset
Clear Event Record
Control Power On
Reclosure Lockout
Reset Trip Counter
Transfer Initiated
PICKUP, TRIP, ALARM, LATCHED ALARM, AND CONTROL EVENT CAUSES
Analog Rate 1 to 2
Breaker Failure
Current Demand
Line Undervoltage 3 to 4
Neg Seq Voltage
Neutral Time OC 1 and 2
Phase Dir Reverse
Power Factor 2
Senstv Gnd Time OC
Underfrequency 1
LOGIC INPUT EVENT CAUSES
52a Contact
Block Freq Decay
Block Neg Seq Time
Block Neutral OC
Block Phase OC
6
Block Restoration
Block Trip Count
Bus Tie Connected
Cold Load Pickup
Remote Close
Setpoint Group 3
Trigger Data Log
WARNING EVENT CAUSES
A/D Virtual Ground
Factory Service
Internal Temp
Relay Not Ready
1
The coil monitor name as programmed is displayed.
2
The pulse output quantity name as programmed is displayed.
3
For User Inputs A through T, the user-defined name is displayed
PATH: ACTUAL VALUES
LAST RESET DATE
[ENTER] for more
After the header message for the last event is a message indicating when the event recorder was last cleared.
6-18
Courtesy of NationalSwitchgear.com
Breaker Closed
Breaker Not Connected
Clear Max Demand
Close Breaker
Display Message
Group 1 to 4 Active
Reset
Reset AR Count
Set Date
Set Time
Transfer Not Ready
Trigger Data Log
Analog Threshold 1 to 2
Apparent Power Demand Arcing Current
Breaker Operation
Bus Undervoltage 1 to 2
Frequency Decay
Ground Dir Reverse
Manual Close Block
Neg Seq Dir Reverse
Neutral Current Level
Neutral Dir Reverse
Out of Sync
Overfrequency
Phase Inst OC 1 and 2
Phase Time OC 1
2
Pulse Output
Reactive Power Demand
Senstv Gnd Inst OC
Trip Coil Monitor
Underfrequency 2
User Input A to T
52b Contact
Block 1 Trip
Block Gnd Inst OC
Block Gnd Time OC
Block Neg Seq Volt
Block Neutral Disp
Block Neutral Time OC 1
Block Neutral Time OC 2
Block Phase Time OC 1
Block Phase Time OC 2
Block Sens Gnd Inst OC
Block Sens Gnd OC
Block Undervolt 1 to 4
Block Underfreq 1 and 2
Bypass Synchrocheck
Cancel Reclosure
Incomer 1 Closed
Incomer 2 Closed
Remote Open
Remote Reset
Setpoint Group 4
Simulate Fault
Trigger Trace
User Input A to T
Analog Output +32V
Clock Not Set
FLASH Corrupt
Force Analog Out
IRIG-B Failure
Not Calibrated
RTC Crystal
Simulation Mode
A4 EVENT RECORDER
LAST RESET DATE
ð
EVENT RECORDER LAST
ENTER
ESCAPE
RESET: Mar 16 1997
750/760 Feeder Management Relay
Breaker Open
Cls From Transfer
Open Breaker
Reset AR Shot Rate
Shots Reduced to 1(3)
Trigger Trace
1
Close Coil Monitor
Ground Inst OC
Neg Seq Inst OC
Neutral Displacement
Overvoltage 1 and 2
Phase Time OC 2
Real Power Demand
Trip Counter
3
UVolt Restore Init
Block 2 Close
Block Ground OC
Block Neutral Inst OC 1
Block Phase Inst OC 1
Block Reclosure
Block Sens Gnd Time OC Block Transfer
Breaker Connected
Cls From Incomer 1
Initiate Reclosure
Selected To Trip
Source Trip
3
UV On Other Source
Dry Contact +32V
Force Relays
Pickup Test
Range: Date in format shown
6 ACTUAL VALUES
Clear Energy Use
Control Power Off
Reclosure 1 to 4
Reset Arc Current
Shots Reduced to L/O
Trip From Transfer
Autoreclose Rate
Cold Load P/U Block
Ground Time OC
Neg Seq Time OC
Neutral Inst OC 1 and 2
Phase Current Level
Power Factor 1
Sens Gnd Dir Reverse
UFreq Restore Init
VT Failure
Block All OC
Block Neg Seq Inst
Block Neutral Inst OC 2
Block Phase Inst OC 2
Block Reset
Bus Tie Closed
Cls From Incomer 2
Local Mode
Setpoint Group 2
Start Demand Interval
Xmfr Lockout
EEPROM Corrupt
Internal RS485
Prototype Software