Toshiba 1600XPi Series Installation And Operation Manual page 82

Single phase - 3.6/5.2/6/8/10/14/18/22 kva
Hide thumbs Also See for 1600XPi Series:
Table of Contents

Advertisement

Standard Models: 14 – 22 kVA
Capacity
General
Typeform
Certifications
Input Characteristics
Input Voltage
1
Input Frequency
Input Capacity
Input /(Max Input) Current @208V
Input /(Max Input) Current @240V
Input Power Factor
Current THD (linear load)
Internal AC Input Breaker rating
Battery Characteristics
Battery Type
Backup time, fully charged @ 0.7
power factor, 77 F
Backup time, fully charged @ 0.85
power factor, 77 F
Recharge Time
Battery Voltage (Nominal)
Output Characteristics
Output Voltage
Output Voltage Regulation
Output Frequency
AUTO/MAN Frequency
Voltage THD
Common-Mode Noise
Rated Load Power Factor
Efficiency (AC-DC-AC)
Voltage Transient
Voltage Transient Recovery
Rated Output Current (rms)
Inverter Overload Capacity
1.
Input/output figures rated for 240 volts unless otherwise stated. Output ratings given for 0.85PF are only valid when
the input voltage is greater than 204 volts; otherwise, ratings given for 0.70PF are applicable.
2.
Battery backup time may vary depending on the operating conditions and ambient temperature at the installation site.
3.
An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is placed in operation.
4.
Subject to update without notice.
5.
Derate to 18.7 kVA (15.9 kW) for 50 Hz operation.
6.
If Vin is below the minimum Vin window, the UPS goes to Battery Mode. If the UPS is in Fault and Vin is below the minimum
Vin window, the UPS goes to Bypass Mode. If UPS is in Bypass mode and Vin is outside the acceptable range, the goes to
Shutdown Mode.
A4
STANDARD MODELS: 14 – 22 KVA (CONT'D)
14 kVA (11.9 kW)
H3BG2L140C61T
67.2 (68.9) A
58.2 (59.7) A
1
18 kVA (15.3 kW)
1
H3BG2L180C61T
UL 1778, CUL, RoHS Compliant
Single-phase, 208/240 VAC, +10%
45-65 Hz (auto-sensing)
14 kVA
0.98 Typical, 0.95 Minimum@ 100% Load
100 A / 277 V
Valve Regulated Lead Acid, Flame Retardant
7 min.
2
7 min.
2
24hr. (full), 12hr.(90%) for internal batteries only
Single-phase, 240/208/120 volts
±0.5Hz/1.0Hz/1.5Hz (factory/authorized service center selectable only)
Factory or authorized service center selectable only
< 3% for linear load; < 6% for non-linear load
0.85 (0.6 - 1.0) lagging
< ±8% (Load of 0 to 100 %)
50 ms to within 2% of nominal
58 A
125%-30 sec./150%-10 sec
1600XPi Series UPS Installation and Operation Manual – 60616-014
1
(to -30% at typical 70% load)
1, 6
(
18 kVA
86.4 (88.1) A
74.9 (76.3) A
< 5%
5 min.
2
288 VDC
= ±3%
< .5 Vrms
>86%
4
75 A
22 kVA (18.7 kW)
1, 5
H3BG2L220C61T
22 kVA
106 (107) A
92.0 (93.0) A
1
125 A / 277 V
5 min.
2
3 min.
2
3
91.6 A