Toshiba 1800 Series User Manual

Toshiba 1800 Series User Manual

1800 series uninterruptible power systems (ups) 1500/2000/2400va
Hide thumbs Also See for 1800 Series:

Advertisement

Quick Links

UNINTERRUPTIBLE POWER SYSTEMS
1800 Series
User Manual
1800 Series
Uninterruptible Power Systems (UPS)
© Copyright 2007 Toshiba International Corporation
All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Toshiba 1800 Series

  • Page 1 UNINTERRUPTIBLE POWER SYSTEMS 1800 Series User Manual 1800 Series Uninterruptible Power Systems (UPS) © Copyright 2007 Toshiba International Corporation All rights reserved.
  • Page 3: Product Use And Warranty Restrictions

    Product use and Warranty restrictions The Toshiba products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These Toshiba products are neither intended nor warranted for usage in equipment that either requires extraordinarily high quality and/or reliability, or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended...
  • Page 4: Qualified Personnel Only

    Please complete the following information and retain for your records. Unless otherwise specified, the warranty period for the UPS or UPS part is 36 months from the shipment date (see Toshiba International Corporation Bill of Lading for shipping date). Unless otherwise specified, the warranty period for a UPS battery is 24 months from the shipment date (see Toshiba International Corporation Bill of Lading for shipping date).
  • Page 5 You may also contact Toshiba by writing to: toshiba international corporation 13131 West Little York Road Houston, Texas 77041-9990 Attn: UPS Product Manager For further information on Toshiba’s products and services, please visit our website at: www.toshiba.com/ind/ © Copyright 2007 Toshiba International Corporation All rights reserved.
  • Page 6: Table Of Contents

    Battery Check Function ..............25 The Function Control Button .............25 communication interface ..............2 Remote Contacts (IBM AS/400) ............26 RS-232C ...................27 Option Card Slot ................28 troubleshooting .................28 Warning/Fault Modes ................28 storage of uPs equipment .............. General Guidelines ................35 Disposal ....................36 1800 Series User Manual...
  • Page 7 Preventive Maintenance ..............37 Parts Replacement ................37 Appendix A: Specifications ..............8 appendix B: system overload ............0 appendix c: Parallel operation............1 appendix d: Bypass undervoltage / overvoltage ......2 Appendix E: 1800 Model/Wire Size specifications ...... Limited Warranty Policy .............. 1800 Series User Manual...
  • Page 8: General Safety Instructions

    WarninGs explosion mark enclosed in a triangle. The explosion warning symbol is used to indicate locations and conditions where molten, exploding parts may cause serious injury or death if the proper precautions are not observed. 1800 Series User Manual...
  • Page 9: Important Safety Instructions

    This manual contains important instructions for all models of the Toshiba 1800 Series UPS. These instructions should be followed during the installation and maintenance of the UPS and its batteries. • The maximum ambient temperature in which this UPS unit should be operated or stored is 104°F (40°C).
  • Page 10: Instructions Importantes Concernant La Sécurité

    Une batterie peut présenter un risque de choc attention électrique, de brûlure par transfert d’énergie. Pour le remplacement, utiliser le même nombre attention de batteries du modèle suivant. L’élimination des batteries est réglementée. attention Consulter les codes locaux à cet effet. 1800 Series User Manual...
  • Page 11: Product Description

    Toshiba’s 1800 Series of on-line Uninterruptible Power Systems (UPS) provides continuous computer-grade AC power in a compact, high performance, energy efficient unit. The UPS assures safe and reliable operation of critical office equipment, minicomputers, and local area networks.
  • Page 12: Power Conditioning

    This protection keeps power-line problems from reaching your load where it can cause equipment to operate erratically, or damage software or hardware. 1800 Series User Manual...
  • Page 13: Inspection/Installation

    Warranty will not apply to units damaged during shipment. 2) Check to see that the rated capacity and the model number specified on the nameplate conform to the order specifications. instaLLation Precautions caution 1800 Series User Manual...
  • Page 14: Operating Precautions

    1) The UPS should not be powered up until this entire manual has been reviewed. 2) The input power source voltage and frequency must be within the allowable range specified in Appendix A. Voltages and frequencies outside of the specified tolerance range may cause internal protection devices to activate. 1800 Series User Manual...
  • Page 15: Layout

    5) Do not use the UPS to provide power to motors that require high starting current or that require a long starting time such as vacuum cleaners and machine tools (unless appropriate sizing is done by a Toshiba applications engineer, or other qualified personnel).
  • Page 16: External Dimensions

    UG1G2L024C6TB typeform UPS. Input Overcurrent Abnormal Bypass ISOLATION OUTPUT XFMR Breaker Reactor/ Input Output Charger/ Inverter Chopper Batteries Output Overvoltage/ Undervoltage Low Battery Current Limit Overheating Level Overload Power Flow 1800 Series User Manual...
  • Page 17 Source Power H3-N 120 VAC Distribution Panel Breaker L1 1 L2 2 terminal Block details This is a detailed view of the UPS terminal block for 120V Input referenced in the connection diagrams above. 120V 120V 1800 Series User Manual...
  • Page 18 DO NOT jumper to terminal 13. note 2: 20V input: If AC input power is 240 V rated, terminals 12 and 13 must be shorted by a jumper wire. DO NOT jumper to terminal 11. 1800 Series User Manual...
  • Page 19: Operating The Ups

    Lights green when normal AC input power is being supplied to the UPS unit. WarninG/FauLt (red lamp) Lights red when the UPS is experiencing an abnormal condition. Battery (red lamp) Lights red to indicate that an abnormal condition exists that is affecting the batteries. 1800 Series User Manual...
  • Page 20: Starting The Ups System

    If the RUN/STOP switch is in the RUN position when the input breaker is switched off, the unit will switch to battery backup mode. The unit will continue to run for as long as the available battery reserves can support the connected loads. 1800 Series User Manual...
  • Page 21 Mode resultant Mode after: switch to Bypass trip Manual Breaker Bypass Backup Backup Shutdown Backup Bypass Shutdown 1800 Series User Manual...
  • Page 22 1800 Series User Manual...
  • Page 23 1800 Series User Manual...
  • Page 24: Battery Backup Time

    However, the chart below gives the times that can be expected from the standard units with batteries in good condition. For longer runtime options contact your Toshiba sales representative or the Toshiba marketing department at 877-867-8773 or by e-mail at toshibaups@tic.toshiba.com.
  • Page 25: Battery Check Function

    2) alarm silence. The alarm silence feature is used to stop the audible alarm from sounding. Any time the audible alarm is sounding, quickly pressing and releasing (in less than 1 sec.) the Function Control button will silence the alarm. 1800 Series User Manual...
  • Page 26: Communication Interface

    Closed during inverter operation Power failure Closed at power failure signal Voltage Current 48 VDC peak 100 mA peak 30 VAC rms 70 mA rms (42 VAC peak) (100 mA peak) DB9 Male Connector Outline (facing connector) 1800 Series User Manual...
  • Page 27: Rs-232C

    Request to Send Input CTS** Clear to Send This pin not used (*) (**) These pins are tied together internally in the UPS. Signals DTR, DSR, RTS, and CTS are not used. DB9 Female Connector Outline (facing connector) 1800 Series User Manual...
  • Page 28: Option Card Slot

    In many cases, after the condition that caused the fault is corrected the unit will automatically transfer back to normal mode. For those cases where the unit does not transfer back automatically contact your Toshiba UPS service representative at 1-877-867-8773 (outside the U.S. call 713-466-0277).
  • Page 29 1800 Series User Manual...
  • Page 30 1800 Series User Manual...
  • Page 31 1800 Series User Manual...
  • Page 32 1800 Series User Manual...
  • Page 33 1800 Series User Manual...
  • Page 34 1800 Series User Manual...
  • Page 35: Storage Of Ups Equipment

    2) For best results, store the UPS in the original shipping container and place on a wood or metal pallet. 3) The optimum storage temperature is 70°F (21° C). Higher ambient temperatures cause UPS batteries to need recharging more frequently. 1800 Series User Manual...
  • Page 36: Disposal

    Please help our Earth by contacting the environmental protection agencies in your area, the battery manufacturer, or call Toshiba toll-free at 877-867-8773 for more information about recycling. 1800 Series User Manual...
  • Page 37: Preventive And Scheduled Maintenance/Parts Replacement

    PreVentiVe and scHeduLed Maintenance/Parts rePLaceMent PreVentiVe Maintenance Toshiba’s 1800 Series of UPS’ have been designed to provide years of trouble- free operation requiring a minimum of preventive maintenance. The best preventive measure is to keep the area around the unit, particularly the air inlet vents, clean and free of moisture and dust accumulations.
  • Page 38: Appendix A: Specifications

    In BYPASS mode if the Input voltage is below 90% or above 110%, the UPS output will be turned off. (See Appendix D: Bypass Under Voltage/Over Voltage) Note 5: The input capacity is computed to include peak battery charging power. 1800 Series User Manual...
  • Page 39 30 to 90%, non-condensing Operating Humidity Up to 3000 ft (1000m) above sea level Altitude 55 dB at max. output, measured 3.3ft (1m) from front panel Acoustical noise Note 1: Currently under development, unit specifications may be changed. 1800 Series User Manual...
  • Page 40: Appendix B: System Overload

    (turning off then on) the input cir- cuit breaker. If the unit is in bypass mode and the output load is not reduced, the unit will eventually go to shutdown. 1800 Series User Manual...
  • Page 41: Appendix C: Parallel Operation

    As shown in the graph, the lower the output load, the lower the input voltage can go before parallel mode is activated. However, the minimum input voltage will always remain at 60% (72 VAC for a 120 VAC system). 1800 Series User Manual...
  • Page 42: Appendix D: Bypass Undervoltage / Overvoltage

    1 second before switching to bypass mode. If the input voltage is out of range the UPS will turn off the output after 1 second rather than switching to bypass. 1800 Series User Manual...
  • Page 43: Appendix E: 1800 Model/Wire Size Specifications

    1800 ModeL/Wire siZe sPeciFications Model Number AC Input, AC Output, Ground, and Selection Jumper Wire UG1A1A015C6TB 12 AWG UG1A1A020C6TB 10 AWG UG1A1A024C6TB 10 AWG UG1G2L024C6TB 14 AWG Note: Tightening torque for all wires is 13 lb-in (1.5 N•m) 1800 Series User Manual...
  • Page 44: Limited Warranty Policy

    TIC Bill of Lading. note 2: For the 1800 Series the warranty applies if the unit is sent and returned (paid for) by the user to/from the Toshiba plant or a Toshiba designated Authorized Service Center.
  • Page 45 VaLVe reGuLated Lead acid (VrLa) Batteries For tosHiBa uPs instaLLation and Maintenance conditions 2. Maximum number Discharge Time Maximum Number of of full charge/dis- Cycles charge cycles (24 months) 30 min. 15 min. 10 min. 5 min. 3. Storage While UPS is in transit or storage it must al- ways be in suitable temperature (see Condi- tion 1).
  • Page 46 TIC officer. THIS WARRANTY REPRESENTS THE ENTIRE AGREEMENT BETWEEN TIC AND USER WITH RESPECT TO THE SUBJECT MATTER HEREIN AND SUPERSEDES ALL PRIOR OR CONTEMPORANEOUS ORAL OR WRITTEN COMMUNICATIONS, REPRESENTATIONS, UNDERSTANDINGS OR AGREEMENTS RELATING TO THIS SUBJECT. 1800 Series User Manual...
  • Page 47 1800 Series User Manual...
  • Page 48 1800 Series User Manual...
  • Page 49 1800 Series User Manual...
  • Page 50 1800 Series User Manual...
  • Page 52 13131 West Little York road, Houston, TX 77041 Tel. 713-466-0277 Fax 713-466-8773 US 800-231-1412 Canada 800-872-2192 Mexico 01/800-527-1204 www.toshiba.com/ind Copyright 9/2007...

This manual is also suitable for:

Ug1a1a015c6tbUg1a1a020c6tbUg1a1a024c6tbUg1g2l024c6tb

Table of Contents