Toshiba 1600XPi Series Installation And Operation Manual
Toshiba 1600XPi Series Installation And Operation Manual

Toshiba 1600XPi Series Installation And Operation Manual

8-22kva battery cabinet
Hide thumbs Also See for 1600XPi Series:
Table of Contents

Advertisement

Quick Links

1600XPi SERIES
8-22kVA BATTERY CABINET
INSTALLATION AND OPERATION MANUAL
SINGLE PHASE – 8/10/14/18/22 kVA: 288Vdc
Part# 64024-006
November 2019

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba 1600XPi Series

  • Page 1 1600XPi SERIES 8-22kVA BATTERY CABINET INSTALLATION AND OPERATION MANUAL SINGLE PHASE – 8/10/14/18/22 kVA: 288Vdc Part# 64024-006 November 2019...
  • Page 3 UNINTERRUPTIBLE POWER SYSTEM - BATTERY CABINET SYSTEM If additional information or technical assistance is required call Toshiba’s Customer Support Center toll free at 1- 877-867-8773 or write to: Toshiba International Corporation, 13131 W. Little York Rd., Houston, TX 77041-9990. Please complete the following information for your records and keep this manual with the equipment:...
  • Page 5: Table Of Contents

    .................................... 13 OWER ABLES BATTERY REPLACEMENT ..............................13 ..................................13 WAPPABLE EXTERNAL LAYOUTS / DIMENSIONS / SHIPPING WEIGHTS ....................15 ..................................15 XTERNAL AYOUTS ....................................15 IMENSIONS ..................................15 HIPPING EIGHTS 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 6 Table 4 1600XPi Parameter Settings for H3B-BC-1825 ...................... 11 Table 5 Field Service Replaceable Parts ..........................13 Table 6 Battery Cabinet Dimensions ........................... 15 Table 7 Battery Cabinet Shipping Weight ..........................15 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 7: General Safety Instructions

    Explosion warnings- The explosion warning symbol is an explosion mark enclosed in a triangle. The Explosion warning symbol is used to indicate locations and conditions where molten, exploding parts may cause serious injury or death if the proper precautions are not observed: 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 8: Important Safety Instructions

    WARNING Installation and servicing of batteries should be performed by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 9: Important Battery Safety Instructions

    Use proper lifting means when moving batteries and wear all appropriate safety clothing and equipment. Do not dispose of lead acid batteries except through channels in accordance with local, state and federal regulations. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 10: Table 2 Battery Type And Quantity

    Table 2 Battery Type and Quantity Model Capacity Type Battery Pack Battery Quantity Quantity H3B-BC-1825 Lead Acid 9AH/12V (FR) L’élimination des batteries est règlementèe. Consultar les codes ATTENTION locaux à cet effet. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 11: Inspection / Storage / Disposal

    It is illegal to dump lead-acid batteries in landfills or dispose of improperly. Please help our Earth by contacting the environmental protection agencies in your area, the battery manufacturer, or call Toshiba toll-free at (877) 867-8773 for more information about recycling.
  • Page 12: Precautions

    2) Before connecting the Battery System to the UPS; switch the ON/OFF switch MCCB2, located on the rear panel of the battery system to the OFF position. (See Sections 4 & 5) 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 13: Operating Precautions

    UPS terminal block. DO NOT jumper terminal 11 to 12 or 13. Connecting Multiple Battery Cabinets Up to two (2) BC-1825 battery cabinets may be connected in parallel with the UPS. See Figure 3, and Sections 4 and 5. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 14: Battery Cabinet Power Cabling

    Battery Cabinet Power Cabling The battery cabinets ship with six-foot long connection cables. Contact Toshiba Customer Support at 1- 877-867-8773 if longer cables are required for your application, or if additional cables or connectors are required. Battery Cabinet Communication (RS-232) Cabling The 1600XPi BC-1825 can be remotely monitored by the UPS by connecting the UPS RS-232 port to the BC-1825(s) as shown below.
  • Page 15: Connection Instructions And Diagrams

    The following diagrams shows the rear view of the 8/10kVA and 14/18/22 kVA UPS with a BC-1825 battery cabinet. NOTE: Use only compatible cabinets! See page 6. CN22 CN23 CN24 1600XPi 14/18/22 kVA UPS BC-1825 BATTERY CABINET Figure 4 Cabling 14/18/22kVA UPS to Battery Cabinet 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 16: Cable Ups To Battery Cabinet(S)

    RS232 to BC port. (Figure 3) 8. Connect Battery Cabinet 2 CN12A to cabinet 1 CN22, 9. Connect Battery Cabinet 2 CN13A to cabinet 1 CN23, 10. Connect Battery Cabinet 2 CN14A to cabinet 1 CN24. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 17: Charger Connection Note

    EPO Operation Pressing the EPO will cause the breaker on the battery cabinet and the UPS, to switch to the OFF position simultaneously, disabling both the battery cabinet and the UPS. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 18: Emergency Power Off (Epo)

    Preventive and Scheduled Maintenance / Part Replacement Preventive Maintenance Toshiba's 1600XPi Series of UPS battery cabinets have been designed to provide years of trouble-free operation requiring a minimum of preventive maintenance. The best preventive measure that the battery cabinet user can take is to keep the area around the unit, particularly the air inlet vents, clean and free of moisture and dust accumulations.
  • Page 19: Power Cables

    5. Lift the new battery pack using the same technique described above to slide the battery pack half-way into the battery pack receptacle. Ensure the battery pack is oriented right-side up. 6. Slowly slide the battery pack the rest of the way into the receptacle. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 20 6.3. Notify the factory if the battery pack still will not fully seat in the receptacle, and a cause cannot be determined. 7. Repeat steps 3-6 for remaining battery packs. 8. Reinstall battery pack retaining plates. 9. Close the 1600XPi Battery Cabinet front door. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 21: External Layouts / Dimensions / Shipping Weights

    Table 6 Battery Cabinet Dimensions Model H3B-BC-1825 39.1 in.(992 mm) 17.5 in.(445 mm) 34.6 in. (880 mm) Shipping Weights Table 7 Battery Cabinet Shipping Weight Model Pounds Kilograms H3B-BC-1825 780 lbs. 354 kg 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 22: 10.0 1600Xpi System Backup Runtime

    1600XPi 22 kVA 1600XPi 8 kVA >300* >300* 1600XPi 10 kVA >300* >300* 1600XPi 14 kVA >300* 1600XPi 18 kVA >300* 1600XPi 22 kVA >300* * Estimated Runtime Exceeds 300 minutes. 1600XPi Series Battery Cabinet Installation and Operation Manual 64024-006...
  • Page 23 SOCIAL INFRASRUCTURE SYSTEMS GROUP POWER ELECTRONICS DIVISION 13131 West Little York Rd., Houston, TX 77041 Tel: 713/466-0277 Fax 713/466-8773 US 877-867-8773 Canada 800/872-2192 Mexico 01/800/527-1204 www.toshiba.com/tic/industrial/uninterruptible-power-systems Printed in the U.S.A.

This manual is also suitable for:

1600xp series

Table of Contents