15.3 BiSS C serial communications

BiSS C specifications
Power supply
5 V ±10% 1.25 W maximum (250 mA @ 5 V)
NOTES:
X
Current consumption figures refer to terminated FORTiS‑S FS
systems. Renishaw encoder systems must be powered from
a 5 Vdc supply complying with the requirements for PELV of
standard IEC 60950‑1
X
Over voltage protection ±10 V.
Ripple 200 mVpp maximum @ frequency up to 500 kHz
FORTiS-S FS grounding and shielding – BiSS C
Encoder
Readhead
cable
* For maximum extension cable length please consult your local Renishaw representative.
IM PORTANT: The shield should be connected to the machine Earth (Field Ground).
IMPORTANT: If the flying lead variant is used or the connector is modified or replaced, the customer must
ensure that both 0 V cores (White and Green) are connected to 0 V. In such situations, care should also
be taken to ensure that 0 V and Earth remain properly insulated from each other throughout the cable run.
26
Customer
electronics
Connector
Extension
cable*
9-way D-type
52
BiSS C (unidirectional) output signals
Function
Signal
5 V
Power
0 V
MA+
MA−
Serial
communications
SLO+
SLO−
Shield
Shield
16
31
Pin-out
Wire colour
9-way D
Brown
4, 5
White
8, 9
Violet
2
Yellow
3
Grey
6
Pink
7
Cable braid
Case